P83.10-2529-07
1 A/C housing top section
2 Electrical connector
3 Electrical connector
4 Bolts
M2/8 Left defroster vent flap actuator motor
M2/9 Right defroster vent flap actuator motor
| Remove/install | ||
1 | Remove instrument panel | ||
2 | Remove sound deadening mat from AC housing | ||
3 | Detach electrical connector (2) from right defroster vent flap actuator motor (M2/9) and electrical connector (3) from left defroster vent flap actuator motor (M2/8) | ||
4 | Carefully lift seal in areas A and remove concealed bolts | Installation: Ensure that seal is properly seated, if necessary glue seal in place. | |
5 | Unhook speaker cable from the guides on the side of the AC housing top section (1) and remove AC housing top section (1) up and out | ||
6 | Remove bolts (4) | ||
7 | Remove right defroster vent flap actuator motor (M2/9) from AC housing top section (1) | ||
8 | Install in the reverse order | ||
9 | Normalize actuator motor and read out and delete fault memory | STAR DIAGNOSIS diagnosis system | |
| Connect STAR DIAGNOSIS and read out fault memory |
Commercially available tools
Referenced documents
- ad0000p200004a Connect STAR DIAGNOSIS and read out fault memory
- ad0000p200004a
- ar6810p1000rt Remove/install dashboard