AR83.10-P-2001Q | Remove/install actuator motor for fresh and recirculated air flaps | 22.8.01 |
MODEL 209 except CODE (581b) Convenience automatic air conditioning
P83.10-2252-09
1 Bolts
2 AC housing
M2/5 Fresh and recirculated air flap actuator motor
3 Electrical connector
Modification notes
| Remove/Install | ||
1 | Remove glove compartment | ||
2 | Remove cover below instrument panel on front passenger side | ||
3 | Remove bolts (1) | ||
4 | Remove fresh and recirculated air flap actuator motor (M2/5) | ||
5 | Separate electrical connection (3) | ||
6 | Install in the reverse order | ||
7 | Connect STAR DIAGNOSIS, normalize fresh and recirculated air flap actuator motor (M2/5), read out fault memory and delete | ||
| Connect STAR DIAGNOSIS and read out fault memory | ||
Diagnosis system STAR DIAGNOSIS | |||
8 | Perform function check |
Commercially available tools
Referenced documents
- ad0000p200004a Connect STAR DIAGNOSIS and read out fault memory
- ad0000p200004a
- ar6810p1400q Remove/install glove box