ar7216d6001ts

Remove/install sliding door hinges

Type ar · topic 72.16 · version 0200 · 2018-07-03

Applies to: Model 907.6/7, 910.6

Where it sits

Function group 3 Body › 72 Doors › 72.16 Sliding doors — Series 907 (models 6**, 7**) · Series 910 (models 6**)

EinPAS 35 Body/frame/detachable parts › 35.35 Door › 35.35.44 Sliding door — Series 907 (models 6**, 7**) · Series 910 (models 6**)

AR72.16-D-6001TS

Remove/install sliding door hinges

18.06.2018

Model

907.6/7, 910.6

Modification notes

04.06.2018

Number of electric sliding door normalization runs changed.

Operation step 8

Remove/install sliding door hinges

Shown on model 907.6 with code T55 (electrical actuation for right sliding door)

15

Release

D72.16-1378-01

Remove/install sliding door hinges

Shown on right sliding door (3)

1

Door stop

2

Bolts

3

Sliding door

D72.16-1423-06

Warning

Risk of injury caused by fingers being jammed or pinched when removing, installing or aligning hoods, doors, trunk lid/rear-end door or sliding roof.

No parts of the body or limbs should be within the operating area when the components are moving.

AS00.00-Z-0011-01A

Topical note

Notes on carrying out repair work in the vehicle interior

AH68.00-N-0001-01S

Remove

1

Fully open left or right sliding door (3).

2

Set release (15) on sliding door (3) to "MAN" position using a suitable screwdriver.

Model 907.6/7
with code T55 (Electric operation of sliding door on right)
Model 907.6/7
with code T56 (Electric operation of sliding door on left)

This deactivates the electric drive of the sliding door (3).

3

Mark installation position of upper or lower door check (1) on sliding door (3).

Model 907.6/7
except code T55 (Electric operation of sliding door on right)
except code T56 (Electric operation of sliding door on left)
Model 910.6

4

Remove screws (2) and take off door check (1).

Install

5.1

Align door check (1) with markings and tighten screws (2) lightly by hand.

Model 907.6/7
except code T55 (Electric operation of sliding door on right)
except code T56 (Electric operation of sliding door on left)
Model 910.6

Screws (2) are tightened to specified tightening torque after adjustment has been checked or after door check (1) has been adjusted.

5.2

Position door check (1) in installation location and tighten screws (2) lightly by hand.

Model 907.6/7
with code T55 (Electric operation of sliding door on right)
Model 907.6/7
with code T56 (Electric operation of sliding door on left)

Screws (2) are tightened to specified tightening torque after door check (1) has been adjusted.

6.1

Check adjustment of the upper and lower door checks (1).

Model 907.6/7
except code T55 (Electric operation of sliding door on right)
except code T56 (Electric operation of sliding door on left)
Model 910.6

Perform check with completely open sliding door (3), engaged door catch and sliding door (3) pulled in direction of travel by hand.
The distances between the door checks (1) and the contact surface on the C-pillar must be identical.

Distance from limit stop to contact surface on C-pillar

*BE72.16-N-1005-01TS

If adjustment is correct:

Tighten screws (2).

Bolt, door check at top to sliding door

*BA72.16-N-1012-01TS

Bolt, door check at bottom to sliding door

*BA72.16-N-1013-01TS

If adjustment is not correct,

Adjust door checks (1).


AR72.16-D-6001-01TS

Feeler gauge

*129589032100

6.2

Adjust door check (1).

Model 907.6/7
with code T55 (Electric operation of sliding door on right)
Model 907.6/7
with code T56 (Electric operation of sliding door on left)

AR72.16-D-6001-01TS

Bolt, door check at top to sliding door

*BA72.16-N-1012-01TS

Bolt, door check at bottom to sliding door

*BA72.16-N-1013-01TS

Feeler gauge

*129589032100

7

Set release (15) on sliding door (3) to "AUTO" position using a suitable screwdriver.

Model 907.6/7
with code T55 (Electric operation of sliding door on right)
Model 907.6/7
with code T56 (Electric operation of sliding door on left)

This reactivates the electric drive of the sliding door (3).

8

Completely open and close sliding door (3) twice with corresponding push button switch.

Model 907.6/7
with code T55 (Electric operation of sliding door on right)
Model 907.6/7
with code T56 (Electric operation of sliding door on left)

For normalization of the electric drive of the sliding door (3).
Keep push button switch pressed throughout normalization run.

Check values for sliding doors

Number

Designation

Model 907.6/7
except code T55 (Electric operation of sliding door on right)
except code T56 (Electric operation of sliding door on left)
Model 910.6

BE72.16-N-1005-01TS

Distance from limit stop to contact surface on C-pillar

mm

2...3

Sliding door

Number

Designation

Model 907.6/7, 910.6

BA72.16-N-1012-01TS

Bolt, door check at top to sliding door

Nm

32

Sliding door

Number

Designation

Model 907.6/7, 910.6

BA72.16-N-1013-01TS

Bolt, door check at bottom to sliding door

Nm

32

Remove/install sliding door hinges

129 589 03 21 00

Feeler gauge

Referenced documents