1 | Mark position of passage (5) on ultrasonic sensor of anti-theft alarm (ATA) on A-pillar paneling (2). |
Dimensions: |
2 | Drill passage (5). |
The diameter of passage (5) is 6 mm. |
Shown on left A-pillar paneling (2) |
S68.30-4716-02
3 | Position retaining plate (4) on A-pillar paneling (2) as shown and tighten with bolt (3). |
The top edge of the retaining plate (4) should be parallel to the top edge of the A-pillar paneling (2). |
4 | Guide electrical wiring harness on ultrasonic sensor (1) through passage of A-pillar paneling (2). |
5 | Clip ultrasonic sensor (1) to retaining plate (4). |
Shown on left A-pillar paneling (2) |
S68.30-4717-12