P54.15-2684-07
1 Electrical connector
2 Nuts
K57/2 Additional battery relay
3 Electrical wiring
4 Nut
| Remove/install | ||
1 | Remove the water collector until the additional battery relay (K57/2) is accessible | ||
2 | Disconnect ground cable from additional battery | ||
3 | Separate electrical connector (1) from additional battery relay (K57/2) | ||
4 | Mark electrical lines (3), unscrew nuts (2) and remove electrical lines (3) | Installation: Observe markings on electrical lines (3). | |
| |||
5 | Unscrew nuts (4) and remove additional battery relay (K57/2) | | |
6 | Install in the reverse order |
Battery
Referenced documents
- ar5410p0007tx Removing, installing auxiliary battery
- ar8325p1402tx Remove/install water collector