P54.15-2366-07
Shown on model 211.0
1 Electrical connector
2 Nuts
K57/2 Additional battery relay
3 Electrical wiring
4 Nut
| Remove/install | ||
1 | Remove water collector at right-hand side until additional battery relay (K57/2) is accessible | ||
2 | Disconnect ground cable from additional battery | ||
3 | Disconnect electrical connector (1) from additional battery relay (K57/2) | ||
4 | Unscrew nuts (2); remove electrical lines (3) and apply markings to them | Installation: Observe markings on electrical lines (3). | |
| |||
5 | Unscrew nuts (4) and remove additional battery relay (K57/2) | | |
6 | Install in the reverse order |
Battery
Referenced documents
- ar5410p0007t Remove/install additional battery
- ar8325p1402t Remove/install water collector