ar5415p2000t

Remove/install additional battery relay

Type ar · topic 54.15 · version 0104 · 2006-03-29

Applies to: MODEL 211.0 /2 /6 up to 31.5.06

Where it sits

Function group 2 Chassis › 54 Electrical system, equipment and instruments › 54.15 Fuse and relay box — Series 211 (models 0**, 2**, 6**)

EinPAS 25 On-board/network/multifunction › 25.20 On-board electrical system › 25.20.11 Control unit/module/relay — Series 211 (models 0**, 2**, 6**)

AR54.15-P-2000T

Remove/install additional battery relay

22.3.06

MODEL 211.0 /2 /6 up to 31.5.06

Remove/install additional battery relay

P54.15-2366-07

Shown on model 211.0

1 Electrical connector

2 Nuts

K57/2 Additional battery relay

3 Electrical wiring

4 Nut

Remove/install

1

Remove water collector at right-hand side until additional battery relay (K57/2) is accessible

AR83.25-P-1402T

2

Disconnect ground cable from additional battery

AR54.10-P-0007T

3

Disconnect electrical connector (1) from additional battery relay (K57/2)

4

Unscrew nuts (2); remove electrical lines (3) and apply markings to them

Installation: Observe markings on electrical lines (3).

*BA54.10-P-1011-01C

5

Unscrew nuts (4) and remove additional battery relay (K57/2)

*BA54.10-P-1010-01C

6

Install in the reverse order

Battery

Number

Designation

Model
211

BA54.10-P-1010-01C

Nut, relay of additional battery to body

M6

Nm

8

BA54.10-P-1011-01C

Nut, line connection to relay of additional battery

M6

Nm

7

Referenced documents