AR54.10-P-1030-03C | Testing quiescent current | If nominal value is not reached: | |
Determine circuit in which quiescent current consumption is too high |
201 589 00 99 00
Electrical connection set
Commercially available tools
Number | Designation | |
WH58.30-Z-1001-09A | Multimeter |
Test step | Test instrument/ | Action/Prerequisite | Nominal value | Possible cause/ | ||
| Observe multimeter limit for measuring current. When the central locking is actuated a current of approx. 10 A flows. | |||||
1 |
W10 | |
G1- | Lock vehicle. Wait approx. 10 minutes (after-running time for electronic components) | Display 0.05 A (50 mA) or 0,09 A (90 mA) , vehicles with alarm system CODE 551. Nominal value reached: | |
Alarm system active when LED in rotary light switch flashes | ||||||
Do not activate any other loads during the test, otherwise observe after-running time of 10 minutes again | ||||||
2 |
W10 | |
G1- | Unlock vehicle. Wait approx. 10 minutes (after-running time for electronic components) | Display 0.05 A (50 mA) or 0.09 A (90 mA) , vehicles with alarm system CODE 551. Nominal value reached: End of test | |
Alarm system inactive when LED in rotary light switch does not flash. | ||||||
Do not activate any other loads during the test, otherwise observe after-running time of 10 minutes again. | ||||||
Referenced documents
- ar5410p103004c Determining circuit with increased quiescent current consumption