AR54.10-P-0019-01LFH

Perform protective earth conductor and insulation resistance test

MODEL

222.163

The resistance/insulation resistance measurement should only be performed after the vehicle has been de-energized.
Otherwise, the test results may be falsified.

The resistance/insulation resistance measurement on the high-voltage component must never be performed between HV+ (positive) and HV- (negative).
The high-voltage component can otherwise be damaged.

A resistance/insulation resistance tester is used for the measurement. The resistance/insulation resistance tester must be checked for proper operation before commencing test work in accordance with the manufacturer's specifications.

Carefully connect the probes of the resistance/insulation resistance tester to the high-voltage connections.
Otherwise the high-voltage connections may be damaged.

Perform protective earth conductor and insulation resistance test

P54.10-4152-08

1

Threaded connection

3

Ground point

2

Protective earth conductor line

4

Ground point

1

Perform a visual inspection to determine whether the protective earth conductor line (2) is connected to the high-voltage battery charger.

2

Perform a visual inspection to determine whether the high-voltage battery potential equalization line is connected to the ground point (3) and high-voltage battery attachment point.

3

Perform a visual inspection to determine whether the high-voltage battery charger potential equalization line is connected to the ground point (4) on the longitudinal member and the high-voltage battery charger attachment point.

4

Check protective earth conductor line (2) at threaded connection (1) on high-voltage battery charger for tight seating.

5

Check high-voltage battery charger potential equalization line at ground point (4) and high-voltage battery charger attachment point for tight seating.

6

Check high-voltage battery potential equalization line at ground point (3) and high-voltage battery attachment point for tight seating.

Perform protective earth conductor and insulation resistance test

SAE charger feed-in socket

L1

Phase L1

N

Neutral conductor

PE

Protective earth conductor

X58/23

Charger feed-in socket

P54.10-4215-11

Perform protective earth conductor and insulation resistance test

7

Calibrate resistance/insulation resistance tester.



8

Open socket flap under right rear taillamp.



9

Open cover of charger feed-in socket (X58/23).


ECE charger feed-in socket

L1

Phase L1

N

Neutral conductor

PE

Protective earth conductor

X58/23

Charger feed-in socket

P54.10-4151-12

Conduct resistance/insulation resistance measurement of HV-AC circuit-1-phase (vehicle socket as measuring point) charger feed-in socket (X58/23)

10

Measure resistance using resistance/insulation resistance tester between protective earth conductor (PE) of charger feed-in socket (X58/23) and ground point (3) in the trunk.

To do so, set the resistance/insulation resistance tester to the resistance testing mode.
Otherwise, components may be damaged.

The test must be carried out if the ground fault circuit interrupter integrated in the charging cable or the ground fault circuit interrupter of the external power supply has been triggered.

Specified value < 1 Ω (+0.9)

11

Measure insulation using resistance/insulation resistance tester between phase L1 (L1) of charger feed-in socket (X58/23) and the protective earth conductor (PE).

To do so, set resistance/insulation resistance tester to 500 V.

The test must be carried out if the ground fault circuit interrupter integrated in the charging cable or the ground fault circuit interrupter of the external power supply has been triggered.

Specified value > 1 MΩ.

12

Measure insulation using resistance/insulation resistance tester between neutral conductor (N) of charger feed-in socket (X58/23) and the protective earth conductor (PE).

The test must be carried out if the ground fault circuit interrupter integrated in the charging cable or the ground fault circuit interrupter of the external power supply has been triggered.

Specified value > 1 MΩ.