The measurement procedure of the caster depends on the equipment. Consult the operation manual of its equipment to be used
1
Position the projector (5) on its support (4)
2
Turn the wheel to the left on the rotating plate (6) by angle (a)
A = 20°
3
Put the projector (5) in the horizontal in the longitudinal direction and tighten the butterfly screw (16)
Check
B40.20-0004-01
W40.20-0032-01
4
Turn the rotating button (29) until level (30) is centered
5
Read the value indicated on the dial ring for caster measurement (32)
For example: 4°
The scale disc to measure the caster (32) is divided into the following measuring fields: "Positive caster" and "negative caster". The "positive caster" measuring range is 0 to +15°. The "negative caster" measuring range is 0 to -3°. One division on the scaled disc represents 10'.
6
Record the measuring value on the alignment form
7
Put the dial ring of measurement (32) at 0 scale to measurement later
W40.20-0037-01
W40.20-0036-01
8
Turn the wheel to the right on the rotating plate (6) by angle (a)
A 20°
9
Repeat the same procedure for work steps 3, 4, 5, and 6
If the nominal values are not reached:
Adjust the caster.
10
Repeat the same procedure for work steps 1 to 11 on the other wheel of the front axle
B40.20-0005-01
11
Support the front axle to prevent falling
12
Loose and remove the nuts (1) and spring clamps (3)
13
Lift and support the chassis frame and lock it in a suitable way
14
Remove wedge (2) and replace it for another one which meets the needs of the described caster
Wedges with different angles are available
15
Lower the chassis frame
Make sure the pin fits correctly into the hole of the wedge