ar3016w1004a

Manual programming of fixed working speed for PTO

Type ar · topic 30.16 · version 0102 · 1998-08-08

Applies to: ENGINE 445.9, 446.9

Where it sits

Function group 1 Engine › 30 Throttle control, speed control systems › 30.16 Throttle control, electronic

EinPAS 15 Engine › 15.45 Engine management › 15.45.1 Basic information

EinPAS 17 Drivetrain/axle › 17.45 Power take-off › 17.45.1 Basic information

Also applies to engines/gearboxes: 445 9**, 446 9**

AR30.16-W-1004A

Manual programming of fixed working speed for PTO

15.11.96

ENGINE 445.9, 446.9

Manual programming of fixed working speed for PTO

1 Vehicle-engine control (FMR) control unit

2 Switch

A Plug connection

B Shop-made set of cables

W30.16-0006-03

Manual programming of fixed working speed for PTO

W30.16-0007-01

A Tempomat lever connector

Setting

Manual programming is only possible on control units of vehicle-engine control (FMR) with sticker 1600 rpm and if the parameterized value manual programming ADR is set to ON

Vehicle parameters with EDC

AR30.16-W-1001-01A

Make manual programing cable for setting the working speed

WF58.50-N-3016-01A

1

Unplug connector (A) to Tempomat lever

2

Connect shop-made set of cables (B) to connector (A)

3

Switch on switch (2)

4

Switch on PTO

GND should exist at connector Ⅲ, 14/3 and 14/4 at FMR control unit

5

Start engine

FMR control unit (1) is switched in idle speed control up to 2800 rpm

6

Increase engine speed at the accelerator

Until desired speed for PTO is reached

7

Switch off switch (2)

Engine speed when switching off is programed as fixed working speed in the FMR control unit.

The term "fixed working speed" is identical with "intermediate speed".

8

Switch off PTO

9

Switch off engine

10

Start engine

11

Switch on PTO

Engine is immediately governed with stored fixed working speed according to RQV characteristics

If the the desired fixed working speed is not stored, inspect circuitry for PTO or repeat setting, as appropriate

12

Switch off engine

13

Switch off ignition

14

Enter "fixed working speed" figure

Enter figure in vacant box of sticker for ADR fixed value; remove FMR control unit to enter figure if necessary

Installing vehicle-engine control (FMR) control unit

AR30.16-W-1001A

Referenced documents