W26.20-1099-09
1 | Housing | 6 | Sealing gasket | Y30 | Electromagnetic valve, split group 2 (MS2) | ||
2 | O-Ring | 7 | Seal | Y33 | Electromagnetic valve for coupling and gear selection 1 (MG1) | ||
3 | O-Ring | A16 | Gear control module (GS) | Y34 | Electromagnetic valve for coupling and gear selection 2 (MG2) | ||
4 | Sealing gasket | Y29 | Electromagnetic valve, split group 1 (MS1) | Y125 | Counter shaft brake electro-magnetic valve | ||
5 | Intermediate plate |
| Remove/install | ||
1 | Remove the gear selection and engagement module |
| |
2 | Remove the gear control unit (GS) (A16) from the housing (1) | Installation: Replace the gasket (4) and apply synthetic grease. | |
.Intermediate plate control unit | |||
Synthetic grease 50 g | |||
3 | Remove the electromagnetic valves of the counter shaft brake (Y125), of the split group 1 (MS1) (Y29), of split group 2 (MS2) (Y30), of coupling and gear selection 1 (MG1) (Y33), and of coupling and gear selection 2 (MG2) (Y34) | Installation: Replace the O-Rings (3) and apply synthetic grease. | |
Synthetic grease 50 g | |||
4 | Remove the intermediate plate (5) from the gear control unit (GS) (A16) | Installation: Replace o O-Ring (2) and the gasket (6), and apply synthetic grease. | |
.Intermediate plate control unit | |||
Synthetic grease 50 g | |||
5 | Install in reverse order | ||
6 | Re-program the gearshift control unit (GS) (A16) |
|
Referenced documents
- ar2620b1005tka Remove/install gate module
- ar5421b0009ta Teach in gear control (GS) control unit