P20.10-0212-06
1 Coolant pump
3 Mating ring
4 Cassette-type seal
5 Impeller
14 Puller
| Removal, installation | ||
1 | Remove coolant pump | ||
2 | Place puller (14) against impeller (5), tension | Tension claws of puller (14) with sleeve, inner 40 mm (shop-made) or suitable hose strap | |
3 | Pull off impeller (5) | If impeller (5) is tight, apply slight pressure to puller (14) when pulling off. | |
4 | Pull off mating ring (3) | With pliers | |
5 | Press out cassette-type seal (4) | Position screwdriver against circumference of cassette-type seal (4) to prise out of coolant pump (1). Do not damage coolant pump (1); use clean rag as a base. | |
6 | Install cassette-type seal (4) | ||
7 | Install in the reverse order | ||
8 | Check cooling system for leaks |
000 589 94 33 00
Puller
Referenced documents
- ar2000p1010ha Inspect cooling system for leaks
- ar2000p1010ha
- ar2010p1271a Remove/install coolant pump
- ar2010p225001a Installing cassette-type seal