ar2000p1050ol

Remove/install low-temperature circuit switchover valve

Type ar · topic 20.00 · version 0100 · 2020-06-05

Applies to: Engine 654 in model 238, 257

Where it sits

Function group 1 Engine › 20 Engine cooling system › 20.00 General — Series 238 · Series 257 · Series 654

EinPAS 15 Engine › 15.25 Engine cooling system › 15.25.13 Line/hose/valve — Series 238 · Series 257 · Series 654

AR20.00-P-1050OL

Remove/install low-temperature circuit switchover valve

18.05.2020

Engine

654 in model 238, 257

Remove/install low-temperature circuit switchover valve

1

Coolant lines

2

Bolts

3

Low-temperature circuit switchover valve

P20.00-A097-06

Warning

Risk of injury to skin and eyes suffering scalding from contact with hot coolantspray. Risk of poisoning from swallowing coolant.

Do not open cooling system unless coolant temperature is below 90 °C. Open cap slowly and release the pressure. Do not pour coolant into beverage containers.
Wear protective gloves, protective clothing and safety glasses.

AS20.00-Z-0001-01A

Topical note

Notes on avoiding damage through contamination and foreign objects

AH00.00-P-5000-01A

Topical note

Information on preventing damage to electronic components due to electrostatic discharge

AH54.00-P-0001-01A

Topical note

Notes on coolant

AH20.00-N-2080-01A

Remove/install

1

Remove front lower engine compartment paneling.


Engine 654 in model 238

AR61.20-P-1105LWE

Engine 654 in model 257

AR61.20-P-1105FR

2

Drain off coolant.


Engine 654 in model 238

AR20.00-P-1142OLC

Engine 654 in model 257

AR20.00-P-1142OIB

3

Remove screws (2).

4

Remove coolant lines (1) at low-temperature circuit switchover valve (3) and seal openings using suitable protective covers.

AR20.20-P-7441-01RQ

Set of protective covers

*001589019100

5

Remove low-temperature circuit switchover valve (3) until electrical connector can be accessed.


Do not crush or kink or subject electric lines to tension.
This will result in damage to the electric lines and can impair their function.

6

Release and disconnect electrical connector at low-temperature circuit switchover valve (3).

7

Install in the reverse order.

Remove/install low-temperature circuit switchover valve

001 589 01 91 00

Set of protective covers

Referenced documents