Represented on vehicle 382.177 |
1 | Compressed air inlet |
2 | Compressed air outlet |
3 | Connection bolt |
4 | Electric connection |
5 | Connection bolt |
6 | Fastening bolt |
7 | Electromagnetic pressure relief valve |
B14.40-0073-05
| Remove/install | ||
1 | Turn off ignition | ||
Notes on compressed air connection systems | . | ||
2 | Detach the electric connection (4) of the pressure limiting solenoid valve (7) | After engine shutdown, compressed air continues flowing through some compressed air lines for approximately 3 min. Start working on the compressed air operating unit after this time. | |
3 | Remove the compressed air inlet line (1) | Firstly, slacken the connection bolt (5) in two turns to release the pressure of the system and then remove it completely. | |
.Compressed air connection system "VOSS 232" | |||
4 | Remove the compressed air outlet line (2) | First, loosen the connection bolt (3) in two turns to release the system pressure and then remove it completely. | |
.Compressed air connection system "VOSS 232" | |||
5 | Remove the pressure limiting solenoid valve (7), unscrewing the fastening nuts (6) | .SCR compressed air limiting solenoid valve on support | |
6 | Install in reverse order | ||
7 | Charge the compressed air system to work pressure |
Referenced documents
- ah0018n000101a Notes on compressed air connection systems