1 | Circulating air switchover valves |
2 | Electrical connections |
3 | Screw/bolts |
P09.40-2531-06
| Remove/install | ||
1 | Open engine hood | ||
2 | Remove upper engine cover | ||
3 | Separate electrical connections (2) | ||
4 | Remove screw/bolt (3) | Bolt, bypass air switchover valve to bypass valve connecting housing | |
5 | Remove circulating air switchover valves (1) | Installation: Install new sealing rings. | |
6 | Install in the reverse order | ||
7 | Read out fault memory using the diagnostic system and clear if necessary | ||
| |||
Danger ! | Risk of accident from vehicle starting off by itself when engine running. Risk of injury (bruises and burns) resulting from working on the engine while it is being started or when it is running. | Secure vehicle to prevent it from starting off by itself. Wear closed and snug-fitting work clothes. Do not touch hot or rotating parts. | |
8 | Carry out an engine test run, checking the engine for proper operation and leaktightness |
Referenced documents
- ad0000p200004b Connect STAR DIAGNOSIS and read out fault memory
- ar8840p1000rg Opening engine hood, moving to upright position and closing
- as0000z000501a Risk of accident from vehicle starting off by itself when engine running. Risk of injury (bruises and burns) resulting from working on the engine while it is being started or when it is running.