1 | Light projector |
2 | Flexible test probe |
S01.00-4508-06
Danger ! | Risk of explosion caused by fuel igniting, risk of poisoning caused by inhaling and swallowing fuel as well as risk of injury to eyes and skin caused by contactwith fuel. | No fires, sparks, open flames or smoking. Pour fuels into suitable and appropriately marked containers only. | |
| Remove | ||
1 | Remove injectors | ||
2 | Move piston of cylinder to be checked to bottom dead center (BDC) | ||
3 | Illuminate cylinders with a light probe | ||
| 000 588 01 21 00 Endoscope | ||
Connect up light projector (1) and insert flexible test probe (2) through the hole for the injectors into the cylinder. | |||
| Check | ||
4 | Check cylinder barrel | ||
| General information on inspecting cylinder walls | ||
If there is wear on the cylinder, the cylinder barrel has become rough or the honing marks are no longer visible. | |||
If the condition of the cylinder barrel is not clearly recognizable. | |||
| |||
Remove respective cylinder head | |||
Remove / install cylinder heads | |||
5 | Check remaining cylinders in an analogue fashion | ||
Observe the firing order. | |||
| Install | ||
6 | Install injectors |
Referenced documents
- ah0100p030001td General information on inspecting cylinder walls
- ar0100s0100se Crank engine
- ar0100s130003se Firing order
- ar0130s5795se Remove / install cylinder heads
- ar0716s1000se Remove/install injectors
- as4700z000101a Risk of explosion caused by fuel igniting, risk of poisoning caused by inhaling and swallowing fuel as well as risk of injury to eyes and skin caused by contactwith fuel.
- ws0100p0097b 000 588 01 21 00 Endoscope