AD82.00-P-5000A | Digital data bus (D2B), diagnosis, troubleshooting | 8.1.99 |
MODEL 129 as of 1.6.98,
168 as of 1.9.98,
170, 202, 208, 210 as of 1.6.98,
215, 220
| Optical fiber, location | Model 129 | |
Model 168 | |||
Model 170 | |||
Models 202, 208.3 | |||
Model 210 | |||
Model 215, 220 | |||
Digital data bus (D2B), diagnosis, previous knowledge | |||
Interrogate the actual configuration of control modules in the vehicle using Hand-Held Tester (HHT) | |||
Connect Hand-Held Tester (HHT), read out fault memory | Except model 215, 220 | ||
Troubleshooting | |||
Complaint | Cause | Notes | Remedy |
D2B ring does not run up | Voltage supply of a D2B component is not ensured | Serves to check the voltage supply of the ring components Wake-up diagnosis can only be carried out when the D2B ring is interrupted | Carry wake-up diagnosis |
D2B ring does not run up | D2B connectors are not plugged in correctly or are dirty | Clean connectors and lock in position | |
D2B ring does not run up and no concrete additional data on the position of the fault is stored in the D2B ring | Optical fiber defective | Check the optical fiber following the sequence of the flow of information, starting at the radio or COMAND | |
D2B ring does not run up and no concrete additional data on the position of the fault is stored in the D2B ring | Transmitter unit at a control module defective Receiver unit at a control module defective | Check the optical fiber following the sequence of the flow of information, starting at the radio or COMAND |
Referenced documents
- ad0000p200003a Connecting Hand-Held Tester (HHT), reading out fault memory
- ad8200p200002a Connecting diagram, network tester, D2B
- ad8200p2000a Digital data bus (D2B), diagnosis, previous knowledge
- gf8200p400001a Fiber optic cable, location
- gf8200p400001b Fiber optic cable, location
- gf8200p400001c Fiber optic cable, location
- gf8200p400001d Fiber optic cable, location
- gf8200p400001e Fiber optic cable, location
- gf8200p400001f Fiber optic cable, location