P91.40-2597-06
1 Electrical connector
2 Automatic belt retractor
3 Bolt
4 Bolt
5 Catches
R12/6 Left 2nd row ETR [GUS] squib
R12/7 Right 2nd row ETR [GUS] squib
| Remove/install | ||
Danger! | Risk of injury caused by performing testing or repair work on airbag or emergency tensioning retractor units. | Store airbag units with deployment side facing up; do not expose to temperatures greater than 100 °C. When working on these units, disconnect the power supply. | |
Danger! | Risk of injury caused by release of spring in the automatic belt retractor is released. | Never disassemble automatic belt retractors. | |
Danger! | Risk of explosion caused by escaping oxyhydrogen gas. Risk of injury caused by caustic burns to eyes, skin and mucous membranes from battery electrolyte (contains diluted sulfuric acid) or metal spatter due to short circuit. Risk of burn injuries caused by short circuit. Risk of poisoning caused by swallowing battery electrolyte (contains diluted sulfuric acid) or absorption of lead over the skin or orifices | No fire, sparks, open flames or smoking. Wear acid-resistant gloves and clothing and safety glasses with side guards. Do not place any conductive objects on the battery and avoid any short circuit from battery positive to ground. Only fill liquid battery electrolyte (diluted sulfuric acid) into suitable and appropriately marked containers. | |
| Notes on performing repair, body work and welding on vehicles with airbags and ETR units | ||
| Assessment of airbag and belt tensioner units in accident vehicles | ||
| Legal regulations on handling and storing airbags and emergency tensioning retractors | ||
1 | Disconnect battery ground cable | ||
2 | Remove moldings from C-pillar | Left or right | |
3 | Detach electrical connector (1) from left 2nd seat row ETR [GUS] squib (R12/6) or right 2nd seat row ETR [GUS] squib (R12/7) | ||
4 | Remove screw (3) | | |
5 | Unscrew bolt (4) | | |
6 | Remove automatic belt retractor (2) | Installation: Note different version (left/right) of the emergency tensioning retractor and its proper location in the catches (5). Noises from the automatic belt reel when rolling up belt are normal. In the event of complaint annoying noises can only be eliminated by replacing seat belt together with emergency tensioning retractor. | |
On no account should oil or grease be used to help eliminate noise. Inertia reels that have been opened are no longer under warranty. If the seat belt with emergency tensioning retractor is replaced, the defective emergency tensioning retractor must be rendered unusable and disposed of properly: | |||
Render seat belt tensioning retractor unusable | |||
| Notes on disposing of airbag and emergency tensioning retractor units | All models | |
7 | Install in the reverse order | ||
8 | Carry out function check | ||
9 | Read out fault memory and erase | Faults stored due to simulations or cables being disconnected for assembly or testing operations, must be processed and erased from the fault memories after work is completed. | |
| Connect STAR DIAGNOSIS and read out fault memory | ||
STAR DIAGNOSIS diagnosis system |
Seat belts/emergency tensioning retractors
Number | Designation | Model 251 | ||
BA91.40-P-1005-01N | Bolt to rear seat belt guide bracket | Nm | 35 | |
BA91.40-P-1007-01N | Screw of rear seat automatic belt retractor to C-pillar/D-pillar | Nm | 35 | |
Commercially available tools
Έγγραφα που αναφέρονται
- ad0000p200004a Σύνδεση Star Diagnosis, ανάγνωση μνήμης βλαβών
- ad0000p200004a
- ah9100p000201m Οδηγίες για τη διεξαγωγή εργασιών επισκευής, φανοποιείας και συγκόλλησης σε οχήματα με μονάδες αερόσακων ή προεντατήρων ζώνης ασ�
- ah9100p000401a Νομικές διατάξεις για το χειρισμό και τη φύλαξη των μονάδων αερόσακων και προεντατήρων ζωνών ασφαλείας
- ah9100p000601b Αξιολόγηση μονάδων αερόσακων και προεντατήρων ζωνών ασφαλείας σε οχήματα μετά από ατύχημα
- ar5410p0003rt
- ar6830p4490rt
- ar9140p0611rt Αχρήστευση των μονάδων προεντατήρων ζωνών ασφαλείας
- as5410z000101a Κίνδυνος πυρκαγιάς/έκρηξης από βραχυκύκλωμα και διαφυγόν εκρηκτικό αέριο. Κίνδυνος εγκαύματος/τραυματισμού λόγω εγκαύματος στα �
- as9100z000101a Κίνδυνος τραυματισμού κατά τις εργασίες ελέγχου ή/και συντήρησης στις μονάδες αερόσακων ή προεντατήρων ζωνών ασφαλείας
- as9100z000201a Κίνδυνος τραυματισμού λόγω χαλάρωσης του ελατηρίου του μηχανισμού περιτύλιξης ζώνης αυτόματης επαναφοράς
- os9100p000101a