si5421b0056a

Service Information: Initial startup of a new control unit for CL/FFB of central locking system control system

Type si · emne 54.21 · version 0100 · 2020-05-18

Gælder for: Model all (TRUCK) with code FZ1 (Remote central locking system) with code FZ2 (Comfort locking system with master key operation)

Ikke tilgængelig på “da”; vises på Engelsk.

Placering

Funktionsgruppe 2 Chassis › 54 El-system, udrustning og instrumenter › 54.21 Styreenheder / moduler — Serie 900 (modeller 9**) · Serie 902 (modeller 9**) · Serie 904 (modeller 918, 919, 924, 925, 938, 943, 957) · Serie 906 (modeller 917, 918, 924, 953)

EinPAS 29 kørselsgodkendelses-/sikringssystem › 29.16 Aflåsning/oplåsning › 29.16.11 Styreenhed/relæ — Serie 900 (modeller 9**) · Serie 902 (modeller 9**) · Serie 904 (modeller 918, 919, 924, 925, 938, 943, 957) · Serie 906 (modeller 917, 918, 924, 953)

EinPAS 45 Data/information › 45.20 Oplysninger/arbejde › 45.20.20 Serviceinformation — Serie 900 (modeller 9**) · Serie 902 (modeller 9**) · Serie 904 (modeller 918, 919, 924, 925, 938, 943, 957) · Serie 906 (modeller 917, 918, 924, 953)

Gælder også for motorer/gearkasser: 139 ***, 254 ***, 256 ***, 272 ***, 276 ***, 282 ***, 457 9**, 541 9**, 542 9**, 608 ***, 700 4**, 700 420, 700 421, 700 422, 700 423, 715 3**, 715 5**, 722 6**, 722 9**, 724 ***, 724 0**, 724 033, 724 044, 724 045, 724 1**, 724 103, 724 114, 724 115, 724 120, 725 ***, 725 0**, 725 035, 725 037, 725 038, 725 085, 725 1**, 739 390, 739 391, 739 395, 739 396, 739 397, 739 398, 739 399, 740 698, 743 3**, 743 4**, 743 498, 746 971, 924 9**, 924 910, 925 9**, 926 9**

SI54.21-B-0056A

Service Information: Initial startup of a new control unit for CL/FFB of central locking system control system

11.05.2020

Model

all (TRUCK)

with code FZ1 (Remote central locking system)

with code FZ2 (Comfort locking system with master key operation)

Commissioning of a new ZV /FFB control module - Central locking control

As informed by ITP 0001/20, the supply of the FFB/ZV control module has been changed.

Now, if in need to replace the control module, it will no longer be necessary to acquire new controls together with the new control module and the current customer controls can be used.

The application of a new control module is carried out via menu: FFB Activations Commissioning the new control module.

Notes on the new process:

Only the first control can be learned in the new control module without a known control already registered in the module.

From the second control it is necessary to authorize using a known control, as usual.

Additional control can be added at any time via the “Register a new transmitter” menu, as usual.

The guidelines described in the letter VPS3-0004/2020 and ITP 0001/20 must also be observed.