si4920g0010a

Service Information: Check/adjust parameters for enabling regeneration of diesel particulate filter

Type si · emne 49.20 · version 0100 · 2016-09-02

Gælder for: Engine 933.9, 935.9 in model 800.210

Ikke tilgængelig på “da”; vises på Engelsk.

Placering

Funktionsgruppe 1 Motor › 49 Udstødningssystem, udstødningsrensning › 49.20 Udstødningsefterbehandling — Serie 800 (modeller 210) · Serie 933 (modeller 9**)

EinPAS 15 Motor › 15.40 Udstødningssystem/udstødningsefterbehandling › 15.40.50 Udstødningsefterbehandlingsenhed — Serie 800 (modeller 210) · Serie 933 (modeller 9**)

EinPAS 45 Data/information › 45.20 Oplysninger/arbejde › 45.20.20 Serviceinformation — Serie 800 (modeller 210) · Serie 933 (modeller 9**)

Gælder også for motorer/gearkasser: 935 9**

SI49.20-G-0010A

Service Information: Check/adjust parameters for enabling regeneration of diesel particulate filter

31.08.2016

Engine

933.9, 935.9 in model 800.210

General notes

We would like to inform you here about the different parameters for enabling regeneration of the diesel particulate filter.

The parameters can be viewed in "ACM control unit Adaptations Parameterization 05 Enable of regeneration", where they can be modified, if necessary, according to the equipment installed and requirements.

Parameter 05.01 "Minimum zone of diesel particulate filter for performing manual regeneration"

This parameter can be used to define the zone (volumetric efficiency or soot/ash content of the diesel particulate filter) above which manual stationary regeneration can be performed.

The higher the value is set, the higher the selected volumetric efficiency or soot/ash content of the diesel particulate filter above which manual regeneration can be performed.

Parameter 05.01

Value

Parameter info

0

Manual stationary regeneration can be performed preventively regardless of the volumetric efficiency.

1

2

Manufacturer default setting

3

Parameter 05.02 "Allow regeneration during operation with power take-off"

This parameter can be used to define whether automatic active regeneration should be allowed when the power take-off is active.

Parameter 05.02

Value

Parameter info

Yes

Regeneration is allowed when the power take-off is active.
(Default setting)

No

Regeneration is not allowed when the power take-off is active.