si4920g0010a

Service Information: Check/adjust parameters for enabling regeneration of diesel particulate filter

Type si · topic 49.20 · version 0100 · 2016-09-02

Applies to: Engine 933.9, 935.9 in model 800.210

Where it sits

Function group 1 Engine › 49 Exhaust system, exhaust gas cleaning › 49.20 Exhaust gas aftertreatment — Series 800 (models 210) · Series 933 (models 9**)

EinPAS 15 Engine › 15.40 Exhaust system/exhaust aftertreatment › 15.40.50 Exhaust aftertreatment unit — Series 800 (models 210) · Series 933 (models 9**)

EinPAS 45 Data/information › 45.20 Information/measures › 45.20.20 Service information — Series 800 (models 210) · Series 933 (models 9**)

Also applies to engines/gearboxes: 935 9**

SI49.20-G-0010A

Service Information: Check/adjust parameters for enabling regeneration of diesel particulate filter

31.08.2016

Engine

933.9, 935.9 in model 800.210

General notes

We would like to inform you here about the different parameters for enabling regeneration of the diesel particulate filter.

The parameters can be viewed in "ACM control unit Adaptations Parameterization 05 Enable of regeneration", where they can be modified, if necessary, according to the equipment installed and requirements.

Parameter 05.01 "Minimum zone of diesel particulate filter for performing manual regeneration"

This parameter can be used to define the zone (volumetric efficiency or soot/ash content of the diesel particulate filter) above which manual stationary regeneration can be performed.

The higher the value is set, the higher the selected volumetric efficiency or soot/ash content of the diesel particulate filter above which manual regeneration can be performed.

Parameter 05.01

Value

Parameter info

0

Manual stationary regeneration can be performed preventively regardless of the volumetric efficiency.

1

2

Manufacturer default setting

3

Parameter 05.02 "Allow regeneration during operation with power take-off"

This parameter can be used to define whether automatic active regeneration should be allowed when the power take-off is active.

Parameter 05.02

Value

Parameter info

Yes

Regeneration is allowed when the power take-off is active.
(Default setting)

No

Regeneration is not allowed when the power take-off is active.