1 | Charge air pipe (cold) |
2 | Charge air pipe (hot) |
3 | Bracket |
4 | Screw |
5 | Bracket |
6 | Turbocharger |
7 | Clip |
8 | Clip |
W09.41-1108-06
Incorrect procedure when mounting the charge air pipes (1, 2) leads to stress between turbocharger (6) and charge air pipe (2). This can damage the turbocharger (6), the charge air pipes (1, 2) or the brackets (3, 5).
In order to ensure mounting without causing stress, the operation steps necessary for installing the charge air pipes must only be carried out in a certain specified sequence.
The new repair instructions "Sequence for mounting the charge air pipes" explain the necessary operation steps in the specified sequence.