GF07.13-P-3006C | DFI limiting quantity injected at WOT function | 19.6.95 |
ENGINE 602.982 in MODEL 210.017 /217 /617
P07.13-0330-76
Design
B17 Intake air temperature sensor
B28 Pressure sensor (intake manifold)
K40 Relay module (bis 02/97)
K40/4 Fuse and relay module
(as of 03/97)
L5/6 Crankshaft position sensor
N3/8 DFI control module
R25/2 IFI/DFI accelerator pedal position sensor
Y23/3 DFI distributor-type injection pump
Y23/3b1 Fuel temperature sensor
Y23/3k1 DFI fuel metering actuator
Y23/3l1 Slide valve actuator
Purpose | Limitation of full load injection quantity. | ||
Function | The DFI control module (N3/8) receives the required input signals from the components mentioned previously and limits the fuel quantity via the DFI fuel metering actuator (Y23/3k1). This minimizes formation of smoke during acceleration and at constant speed. | ||
| Relay module (K40), location/design/purpose/function | up to 02/97 | |
| Fuse and relay module (K40/4), location/purpose,function | as of 03/97 | |
| DFI control module (N3/8) | ||
| Crankshaft position sensor (L5/6), location/design/purpose/function | ||
| IFI/DFI accelerator pedal position sensor (R25/2), design/purpose/function | ||
| Pressure sensor (B28), location/design/purpose/function | ||
| Intake air temperature sensor (B17), location/design/purpose/function | ||
| DFI distributor-type injection pump (Y23/3), design/purpose/function | ||
| Fuel temperature sensor (Y23/3b1), location/purpose/function | ||
| Fuel metering control (DE), purpose/design/function | ||
| DFI fuel metering actuator (Y23/3k1), location/design/purpose/function |
Henviste dokumenter
- gf0702p5002c
- gf0704p2100h Temperaturføler indsugningsluft placering/opgave/opbygning/funktion
- gf0704p4116h Positionsføler krumtapaksel placering/opgave/opbygning/funktion
- gf0704p5008c
- gf0704p5014h
- gf0704p5029h Føler for korrekt værdi placering/opgave/opbygning/funktion
- gf0713p3101h
- gf0713p3102c
- gf0713p3141h Sikrings- og relæmodul placering/opgave/funktion
- gf0713p3160c
- gf0713p3163ac