Number | Designation | Engine 103.940 | Engine 103.941 | |||
BE07.32-P-2001-01B | Engine temperature | Oil | °C | 60 | 60 | |
Coolant | °C | - | - | |||
Conditioning | Time | s | 90 | 90 | ||
Engine speed | rpm | 3700 | 3700 | |||
Number of cylinders | 6 | 6 | ||||
Number of pulses | per engine revolution | 3 | 3 | |||
Idling speed | rpm | 600...800 | 600...800 | |||
Ignition angle with vacuum | with the engine idling | °CA v. TDC | 7...11 | 7...11 | ||
Closed-loop mixture control | at idle | % | - | - | ||
pulse duty factor | at increased rotational speed: rpm 2500 | % | - | - | ||
Alternate procedure | % | λ (λ2500)10 | λ (λ2500)10 | |||
Base method | Interference factor | mbar | > 450 | - | ||
at engine speed | rpm | 500...1100 | 500...1100 | |||
Lambda control duty cycle replacement method | Voltage at idle speed | Volts | 2...10 | 2...10 | ||
CO specification | at increased idle speed: rpm 2200...2800 | % | 0,3 | 0,3 | ||
Lambda mixture specification | at increased idle speed: rpm 2200...2800 | 0.97...1.03 | 0.97...1.03 | |||
CO specification | at idle | % | 0,5 | 0,5 | ||
Test values of EI specified values K-jetronic
Number | Designation | Engine 103.942 | Engine 103.943 | |||
BE07.32-P-2001-01B | Engine temperature | Oil | °C | 60 | 60 | |
Coolant | °C | - | - | |||
Conditioning | Time | s | 90 | 90 | ||
Engine speed | rpm | 3700 | 3700 | |||
Number of cylinders | 6 | 6 | ||||
Number of pulses | per engine revolution | 3 | 3 | |||
Idling speed | rpm | 600...800 | 600...800 | |||
Ignition angle with vacuum | with the engine idling | °CA v. TDC | 7...11 | 7...11 | ||
Closed-loop mixture control | at idle | % | - | - | ||
pulse duty factor | at increased rotational speed: rpm 2500 | % | - | - | ||
Alternate procedure | % | λ (λ2500)10 | λ (λ2500)10 | |||
Base method | Interference factor | mbar | > 450 | > 450 | ||
at engine speed | rpm | 500...1100 | 500...1100 | |||
Lambda control duty cycle replacement method | Voltage at idle speed | Volts | 2...10 | 2...10 | ||
CO specification | at increased idle speed: rpm 2200...2800 | % | 0,3 | 0,3 | ||
Lambda mixture specification | at increased idle speed: rpm 2200...2800 | 0.97...1.03 | 0.97...1.03 | |||
CO specification | at idle | % | 0,5 | 0,5 | ||
Test values of EI specified values K-jetronic
Number | Designation | Engine 103.981 | Engine 103.982 | |||
BE07.32-P-2001-01B | Engine temperature | Oil | °C | 60 | 60 | |
Coolant | °C | - | - | |||
Conditioning | Time | s | 90 | 90 | ||
Engine speed | rpm | 3700 | 3700 | |||
Number of cylinders | 6 | 6 | ||||
Number of pulses | per engine revolution | 3 | 3 | |||
Idling speed | rpm | 550...750 | 550...750 | |||
Ignition angle with vacuum | with the engine idling | °CA v. TDC | 6...11 | 6...11 | ||
Closed-loop mixture control | at idle | % | - | - | ||
pulse duty factor | at increased rotational speed: rpm 2500 | % | - | - | ||
Alternate procedure | % | λ (λ2500)10 | λ (λ2500)10 | |||
Base method | Interference factor | mbar | - | - | ||
at engine speed | rpm | 500...1100 | 500...1100 | |||
Lambda control duty cycle replacement method | Voltage at idle speed | Volts | 2...10 | 2...10 | ||
CO specification | at increased idle speed: rpm 2200...2800 | % | 0,3 | 0,3 | ||
Lambda mixture specification | at increased idle speed: rpm 2200...2800 | 0.97...1.03 | 0.97...1.03 | |||
CO specification | at idle | % | 0,5 | 0,5 | ||
Test values of EI specified values K-jetronic
Number | Designation | Engine 103.983 | Engine 103.984 | |||
BE07.32-P-2001-01B | Engine temperature | Oil | °C | 60 | 60 | |
Coolant | °C | - | - | |||
Conditioning | Time | s | 90 | 90 | ||
Engine speed | rpm | 3700 | 3700 | |||
Number of cylinders | 6 | 6 | ||||
Number of pulses | per engine revolution | 3 | 3 | |||
Idling speed | rpm | 550...750 | 600...800 | |||
Ignition angle with vacuum | with the engine idling | °CA v. TDC | 6...11 | 6...11 | ||
Closed-loop mixture control | at idle | % | - | - | ||
pulse duty factor | at increased rotational speed: rpm 2500 | % | - | - | ||
Alternate procedure | % | λ (λ2500)10 | λ (λ2500)10 | |||
Base method | Interference factor | mbar | > 450 | > 450 | ||
at engine speed | rpm | 500...1100 | 500...1100 | |||
Lambda control duty cycle replacement method | Voltage at idle speed | Volts | 2...10 | 2...10 | ||
CO specification | at increased idle speed: rpm 2200...2800 | % | 0,3 | 0,3 | ||
Lambda mixture specification | at increased idle speed: rpm 2200...2800 | 0.97...1.03 | 0.97...1.03 | |||
CO specification | at idle | % | 0,5 | 0,5 | ||
Test values of EI specified values K-jetronic
Number | Designation | Engine 103.985 | Engine 103.987 | |||
BE07.32-P-2001-01B | Engine temperature | Oil | °C | 60 | 60 | |
Coolant | °C | - | - | |||
Conditioning | Time | s | 90 | 90 | ||
Engine speed | rpm | 3700 | 3700 | |||
Number of cylinders | 6 | 6 | ||||
Number of pulses | per engine revolution | 3 | 3 | |||
Idling speed | rpm | 550...750 | 620...820 | |||
Ignition angle with vacuum | with the engine idling | °CA v. TDC | 6...11 | 6...10 | ||
Closed-loop mixture control | at idle | % | - | - | ||
pulse duty factor | at increased rotational speed: rpm 2500 | % | - | - | ||
Alternate procedure | % | λ (λ2500)10 | λ (λ2500)10 | |||
Base method | Interference factor | mbar | > 450 | - | ||
at engine speed | rpm | 500...1100 | 500...1100 | |||
Lambda control duty cycle replacement method | Voltage at idle speed | Volts | 2...10 | 2...10 | ||
CO specification | at increased idle speed: rpm 2200...2800 | % | 0,3 | 0,3 | ||
Lambda mixture specification | at increased idle speed: rpm 2200...2800 | 0.97...1.03 | 0.97...1.03 | |||
CO specification | at idle | % | 0,5 | 0,5 | ||
Test values of EI specified values K-jetronic
Number | Designation | Engine 104.980 | Engine 104.981 | |||
BE07.32-P-2001-01B | Engine temperature | Oil | °C | 60 | 60 | |
Coolant | °C | - | - | |||
Conditioning | Time | s | 90 | 90 | ||
Engine speed | rpm | 3700 | 3700 | |||
Number of cylinders | 6 | 6 | ||||
Number of pulses | per engine revolution | 3 | 3 | |||
Idling speed | rpm | 600...800 | 600...800 | |||
Ignition angle with vacuum | with the engine idling | °CA v. TDC | 6...10 | 6...10 | ||
Closed-loop mixture control | at idle | % | 50 (20) | 50 (20) | ||
pulse duty factor | at increased rotational speed: rpm 2500 | % | 50 (20) | 50 (20) | ||
Alternate procedure | % | - | - | |||
Base method | Interference factor | mbar | > 450 | > 450 | ||
at engine speed | rpm | 500...1100 | 500...1100 | |||
Lambda control duty cycle replacement method | Voltage at idle speed | Volts | 2...10 | 2...10 | ||
CO specification | at increased idle speed: rpm 2200...2800 | % | 0,3 | 0,3 | ||
Lambda mixture specification | at increased idle speed: rpm 2200...2800 | 0.97...1.03 | 0.97...1.03 | |||
CO specification | at idle | % | 0,5 | 0,5 | ||