AR91.60-D-0611-02A | Deployment of removed airbag units | ||
Warning | Risk of injury caused by performing testing or repair work on airbag or emergency tensioning retractor units. | Store airbag units with deployment side facing up; do not expose to temperatures greater than 100 °C. When working on these units, disconnect the power supply.Model 901, 902, 903, 904, 905Nicht gültig für die Länder A, CH, D | |
Warning | Risk of injury caused by performing testing or repair work on airbag or emergency tensioning retractor units. | Store airbag units with deployment side facing up; do not expose to temperatures greater than 100 °C. When working on these units, disconnect the power supply.Model 415, 447, 448, 636, 639, 906, 909Nicht gültig für die Länder A, CH, D | |
Topical note | Notes on controlled deployment of airbag, sidebag and emergency tensioning retractor units |
126 589 00 90 00
Ignition unit
2 | Pressure switch, battery control |
3 | Pressure switch, deployment |
4 | Rotary switch |
5 | Deployment indicator lamp |
7 | Plug connector, adapter cable |
8 | 2-pin plug connector |
P91.60-0219-01
Use of ignition device
1 | Plug 2-pin plug connection (8) into squib of airbag unit to be scrapped. |
Maintain safe distance of at least 10 m to airbag unit to be scrapped. |
2 | Move rotary switch (4) to position "1". |
3 | Press the battery control pressure switch (2) and deployment pressure switch (3) simultaneously. |
After a successful ignition, the deployment indicator lamp (5) lights up. |
For airbag units with 2 squibs, both squibs must be deployed. To do so, repeat operation steps 1 to 3 after plugging the ignition line into the second squib. |
Henviste dokumenter
- ah9160p061102p Oplysninger om kontrolleret udløsning af airbag-, sideairbag- og selestrammerenheder
- as9100z000101a Fare for personskade ved kontrol- og reparationsarbejde på airbag- eller selestrammerenheder