ar8610p0104a

Remove/install extinguishing agent tank squib

Type ar · emne 86.10 · version 0102 · 2009-05-26

Gælder for: MODEL 463.236 /236 with CODE (979) Special protection version with CODE (ZS6) Special protection version FB6 with fire extinguishing system MODEL 463.248 /248 with CODE (979) Special protection version with CODE (ZS7) Special protection version FB7 with fire extinguishing system

Ikke tilgængelig på “da”; vises på Engelsk.

Placering

Funktionsgruppe 3 Karrosseri › 86 Nødudstyr, handicapvenligt udstyr, sanitært udstyr, køkken › 86.10 Nødudstyr — Serie 463 (modeller 236, 248)

EinPAS 27 Passive sikkerhedssystemer › 27.21 Brandslukningssystem/brandmeldesystem › 27.21.50 Beholder — Serie 463 (modeller 236, 248)

AR86.10-P-0104A

Remove/install extinguishing agent tank squib

30.4.09

MODEL 463.236 /236
with CODE (979) Special protection version
with CODE (ZS6) Special protection version FB6
with fire extinguishing system

MODEL 463.248 /248
with CODE (979) Special protection version
with CODE (ZS7) Special protection version FB7
with fire extinguishing system

Remove/install extinguishing agent tank squib

P86.10-2105-11

Shown on extinguishing agent tank, left side

1 Extinguishing agent tank 1

R42 Extinguishing agent reservoir squib 1

R42x1 Extinguishing agent tank 1 squib electrical connector

Remove/install

Notes on squib on extinguishing agent tank

AH86.10-P-0001-04A

1

Switch off ignition

2

Remove extinguishing agent tank cover

AR86.10-P-0103A

3

Disconnect electrical connector on extinguishing agent tank 1 squib (R42x1) or electrical connector on extinguishing agent tank 2 squib (R42/1x1)

When working on squibs always wear eye protection to avoid eye injuries.

To prevent the fire extinguishing system from being actuated, first disconnect electrical connector from extinguishing agent tank 1 squib (R42x1) or electrical connector from extinguishing agent tank 2 squib (R42/1x1) as first operation step.

4

Remove extinguishing agent tank 1 squib (R42) from extinguishing agent tank 1 (1) or extinguishing agent tank 2 squib (R42/1) from extinguishing agent tank 2

When working on squibs always wear eye protection to avoid eye injuries.

Installation: Secure nuts with locking plates to prevent unscrewing by themselves.

*BA86.10-P-1006-01A

5

Install in the reverse order

Checking

6

Check extinguishing agent tank 1 squib (R42) or extinguishing agent tank 2 squib (R42/1)

When working on squibs always wear eye protection to avoid eye injuries.

AR86.10-P-0121A

Fire extinguishing system

Number

Designation

Model
463.236/248 with
code 979 and
fire extinguishing system

BA86.10-P-1006-01A

Nut, housing on squib to extinguishing agent tank

Nm

10

Henviste dokumenter