1 | Fluid reservoir |
2 | Union nuts |
3 | Nuts |
W83.30-1095-12
Danger ! | Risk of explosion caused by welding or soldering work on closed air conditioning system. Risk of poisoning caused by inhaling overheated refrigerant vapors. Risk of injury to skin and eyes caused by contact with liquid refrigerant. | Never perform welding work on or near a closed air conditioning system. No smoking or open flames. Wear safety glasses and protective gloves. Work only in well ventilated areas. Carry out repair work on the air conditioning system circuit only after the system has been drained. | |
| Protect air conditioning circuit and components from moisture when carrying out repair work | ||
| Notes on handling refrigerant R134a | ||
| Remove/install | ||
1 | Drain air conditioning system | ||
2 | Unscrew union nuts (2) and remove refrigerant lines from fluid reservoir (1) | Do not bend refrigerant lines. | |
Installation: Replace gaskets. | |||
Union nut for refrigerant lines to fluid reservoir | |||
3 | Unscrew nuts (3) | Nut, fluid reservoir to bracket | |
4 | Remove fluid reservoir (1) | Installation: Replace O-rings. | |
If the fluid reservoir (1) is replaced | |||
| |||
Add oil filling capacity of refrigerant circuit | |||
Additional oil filling quantity after replacing fluid reservoir | |||
5 | Disconnect electrical connector from fluid reservoir (1) | Installation: Replace cable tie. | |
6 | Install in the reverse order | ||
7 | Check air conditioning for proper operation |
Henviste dokumenter
- ah8330n000301a Oplysninger om håndtering af kølemidlet R134a
- ah8330n000501a Klimaanlæggets kredsløb og komponenter skal beskyttes mod fugt ved reparationer
- ar8330w1760a Tømning, udluftning, ny påfyldning af klimaanlæg samt kontrol af funktion og tæthed
- as8300z000101a Fare for eksplosion ved svejse- og loddearbejde på det lukkede klimaanlæg. Fare for forgiftning ved indånding af overophedet kølemiddeldamp. Fare for personskade ved hud- og øjenkontakt med flydende kølemiddel