Modification notes |
02.12.2016 | Total filling capacity - refrigerant | Model 415 except code HX1 with code H06 or code HH9 | BF83.00-N-1007-01B |
17.01.2017 | Compressor oil changed. | Operation step 6 | |
14.11.2018 | Total filling capacity - refrigerant | BF83.00-N-1007-01B | |
23.05.2019 | Total filling capacity - refrigerant | BF83.00-N-1007-01B |
Shown on model 415 with engine 607 |
1 | Air conditioning service unit |
2 | Manometer battery |
3 | Connector |
S83.30-4554-06
Warning | Risk of poisoning caused by inhaling overheated refrigerant vapors from an air conditioning system containing R134a. Risk of injury to skin and eyes caused by contact with liquid R134a refrigerant and when working on pressurized parts | Never perform welding work on or near a closed air conditioning system. No smoking or open flames. Wear safety glasses and protective gloves. Work only in well ventilated rooms. Carry out repair work on the air conditioning system circuit only after the system has been evacuated. | |
Topical note | Procedure for a damaged or leaky air conditioning system | ||
Topical note | Protect air conditioning circuit and components from moisture when carrying out repair work | ||
Notes on handling refrigerant R134a | |||
Connect | |||
1 | Connect air conditioning service unit (1) with connector (3) at Schrader valve of refrigerant line | ||
| 000 588 04 82 00 Air conditioning service unit R134a | ||
When connecting and when operating the air conditioning service unit (1) the complete work procedure must be conducted in accordance with the operator's manual as issued by the manufacturer. | |||
Draining | |||
2 | Drain air conditioning system | The volume of compressor oil extracted must be documented. | |
| Check | ||
3 | Check desiccant cartridge for re-usability | ||
Topical note | Protect air conditioning circuit and components from moisture when carrying out repair work | ||
If necessary. | |||
| |||
Replace drier cartridge. | |||
Evacuate | |||
4 | Use the air conditioning service unit (1) to clean the refrigerant and evacuate the refrigerant circuit | ||
5 | Check vacuum with air conditioning service unit (1) | If the air conditioning service unit (1) shows a fault message, then this is an indication that there is a leak in the refrigerant circuit. | |
| |||
Check air conditioning system for leakage. | |||
Filling | |||
6 | Add new compressor oil to the refrigerant circuit according to the oil filling quantity noted during extraction | ||
| Compressor oils (specification 362.1) | ||
| |||
| |||
| |||
Depending on the repair case, the oil filling quantity may need to be adjusted accordingly. | |||
Compressor oil refill quantity when replacing condenser | |||
Compressor oil refill quantity when replacing evaporator | |||
Compressor oil refill quantity when replacing desiccant cartridge | |||
Compressor oil refill quantity when replacing refrigerant line | |||
Refill quantity of compressor oil when air conditioning system is suddenly emptied (e.g. line break) | |||
7 | Fill air conditioning system using air conditioning service unit (1) | ||
| Refrigerant (specification 361.0) | ||
Total filling capacity - refrigerant | |||
| Check | ||
8 | Run pressure test using air conditioning service unit (1) | In the event of a pressure drop during the pressure test. | |
| |||
Check air conditioning system for leakage. | |||
Disconnect | |||
9 | Disconnect air conditioning service unit (1) with connector (3) from Schrader valve of refrigerant line | ||
| Check | ||
Warning | Risk of accident from vehicle starting off by itself when engine running. Risk of injury (bruises and burns) resulting from working on the engine while it is being started or when it is running. | Secure vehicle to prevent it from starting off by itself. Wear closed and snug-fitting work clothes. Do not touch hot or rotating parts. | |
10 | Run engine at idle speed for about 4 minutes and check all the component functions which are of relevance for proper operation of the air conditioning system |
Henviste dokumenter
- ah8330n000301a Oplysninger om håndtering af kølemidlet R134a
- ah8330n000401a Fremgangsmåde ved beskadiget eller utæt klimaanlæg
- ah8330n000501a Klimaanlæggets kredsløb og komponenter skal beskyttes mod fugt ved reparationer
- ar8330s1761c
- ar8330s6525c
- as0000z000501a Fare for ulykke ved automatisk igangsætning når motoren kører. Fare for personskade på grund af knusning og forbrænding, hvis der arbejdes mens motoren startes eller kører
- as8300z000601a Fare for forgiftning ved indånding af overophedede kølemiddeldampe fra et klimaanlæg, der er påfyldt R134a. Fare for personskade ved hud- og øjenkontakt med flydende kølemiddel R134a og ved håndtering af dele, der er under tryk.
- bb0040p036100a
- bb0040p036201a
- ws8300p0031b