P83.30-A067-09
1 | Condenser | 2 | Refrigerant lines | 3 | Charge air cooler |
Danger | Risk of death when working on component parts and systems with U >= 30 V alternating voltage (AC) or U >= 60 V direct voltage (DC) | Do not touch damaged or defective live component parts and lines or non-insulated electrical connections and lines. | |
Danger | Risk of fire due to ignition of R1234yf refrigerant on hot components. Risk of poisoning caused by inhaling overheated refrigerant vapors. Risk of injury to skin and eyes caused by contact with escaped R1234yf refrigerant and when working on pressurized parts. Risk of explosion due to formation of ignitable refrigerant/air mixtures | Never perform welding work on or near a closed air conditioning system. No smoking or open flames. Wear safety glasses and protective gloves. Work only in well ventilated rooms. Carry out repair work on the air conditioning system circuit only after the system has been evacuated. | |
Caution | Risk of injury caused by scraping or cutting body parts on sharp vehicle parts | Always wear protective gloves when working on or near sharp and non-deburred vehicle parts. | |
Topical note | General information on vehicles with high-voltage on-board electrical system and/or lithium-ion battery and/or gaseous-fuel drive system as well as personal protective equipment | ||
Topical note | Procedure for a damaged or leaky air conditioning system | ||
Topical note | Protect air conditioning circuit and components from moisture when carrying out repair work | ||
Notes on handling refrigerant R1234yf | |||
| Remove/install | ||
1 | Remove voltage of high-voltage on-board electrical system. | ||
2 | Discharge air conditioning system. | ||
3 | Remove high voltage components coolant radiator. | ||
4 | Remove refrigerant lines (2) from condenser (1) and seal openings with suitable stop plugs. | Installation: Replace gaskets. | |
Nut, refrigerant line to condenser | |||
Assembly tool | |||
Record plug | |||
5 | Unclip condenser (1) from charge air cooler (3) (arrows A). | ||
6 | Remove condenser (1). | ||
| Check | ||
7 | Check condenser (1) for damage. | If damage is identified, | |
| |||
Replace condenser (1). | |||
8 | Install in the reverse order. |
000 589 93 63 00
Assembly tool
129 589 00 91 00
Record plug
Henviste dokumenter
- ah0000z030001a Generelle oplysninger ved køretøjer med højvoltsnet og/eller litium-ion-batteri og/eller gasdrivsystem samt personligt beskyttelsesudstyr
- ah8330n000401a Fremgangsmåde ved beskadiget eller utæt klimaanlæg
- ah8330n000501a Klimaanlæggets kredsløb og komponenter skal beskyttes mod fugt ved reparationer
- ah8330p000302a Oplysninger om håndtering af kølemiddel R1234yf
- ar0850p0044mfh
- ar4770p1000mfh
- ar8330p1760mfa
- as0000z001701a Fare for personskade på grund af snitsår eller hudafskrabninger grundet skarpkantede køretøjsdele
- as0000z003501a Livsfare ved arbejde på komponenter og systemer med U >= 30 V vekselspænding (AC) eller U >= 60 V jævnspænding (DC)
- as8300z000701a Brandfare som følge af antænding af kølemiddel R1234yf på varme dele. Fare for forgiftning ved indånding af overophedet kølemiddeldamp. Fare for personskade ved hud- og øjenkontakt med frigjort kølemiddel R1234yf og ved håndtering