Modification notes |
20.03.2020 | Air conditioning/automatic air conditioning | BF83.00-P-1001-01P | |
11.06.2020 | Air conditioning/automatic air conditioning | MODEL 177.1 (except 177.186) up to model year 2020 except code 2U8 (alternative refrigerant) | BF83.00-P-1001-01P |
11.06.2020 | Air conditioning/automatic air conditioning | MODEL 177.1 (except 177.186) up to model year 2020 with code 2U8 (alternative refrigerant) | BF83.00-P-1001-01P |
09.07.2020 | Air conditioning/automatic air conditioning | Model 177.0 (except 177.053/054/086), 177.1 (except 177.186) up to model year 2020 with code 2U8 (alternative refrigerant) | BF83.00-P-1001-01P |
09.07.2020 | Air conditioning/automatic air conditioning | Model 177.0 (except 177.053/054/086), 177.1 (except 177.186) up to model year 2020 except code 2U8 (alternative refrigerant) | BF83.00-P-1001-01P |
1 | Plugs |
2 | Filling connection |
3 | Service coupling |
4 | Service coupling |
P83.30-5187-06
Danger | Risk of fire due to ignition of R1234yf refrigerant on hot components. Risk of poisoning caused by inhaling overheated refrigerant vapors. Risk of injury to skin and eyes caused by contact with escaped R1234yf refrigerant and when working on pressurized parts. Risk of explosion due to formation of ignitable refrigerant/air mixtures | Never perform welding work on or near a closed air conditioning system. No smoking or open flames. Wear safety glasses and protective gloves. Work only in well ventilated rooms. Carry out repair work on the air conditioning system circuit only after the system has been evacuated. | |
Warning | Risk of poisoning caused by inhaling overheated refrigerant vapors from an air conditioning system containing R134a. Risk of injury to skin and eyes caused by contact with liquid R134a refrigerant and when working on pressurized parts | Never perform welding work on or near a closed air conditioning system. No smoking or open flames. Wear safety glasses and protective gloves. Work only in well ventilated rooms. Carry out repair work on the air conditioning system circuit only after the system has been evacuated. | |
Danger | Risk of explosion caused by welding or soldering work on closed air conditioning system. Risk of poisoning caused by inhaling overheated refrigerant vapors. Risk of injury to skin and eyes caused by contact with liquid refrigerant. | Never perform welding work on or near a closed air conditioning system. No smoking or open flames. Wear safety glasses and protective gloves. Work only in well ventilated areas. Carry out repair work on the air conditioning system circuit only after the system has been drained. | |
Topical note | Protect air conditioning circuit and components from moisture when carrying out repair work | ||
Topical note | Procedure for a damaged or leaky air conditioning system | ||
Notes on handling refrigerant R134a | |||
Notes on handling refrigerant R1234yf | |||
Draining | |||
1 | Unscrew plugs (1). | ||
2 | Connect service couplings (3, 4) of air conditioning service unit to corresponding filler connections (2). | ||
| 000 588 04 82 00 Air conditioning service unit R134a | ||
| 000 588 10 82 00 R1234yf air conditioning service unit | ||
When operating the air conditioner, proceed in accordance with the manufacturer's operator's manual. | |||
3 | Extract refrigerant. | ||
| 000 588 04 82 00 Air conditioning service unit R134a | ||
| 000 588 10 82 00 R1234yf air conditioning service unit | ||
4 | Note down quantity of extracted refrigerant as well as compressor oil. | ||
5 | Check receiver drier for re-usability, replace if necessary. | Model 118 with engine 139, 260, 282, 608, 654 | |
Topical note | Protect air conditioning circuit and components from moisture when carrying out repair work | ||
Model 118, 177, 247.7 with engine 139 | |||
Model 118, 177, 247 with engine 608, 654 | |||
Model 118, 177 with engine 260, 282 | |||
| |||
Evacuate | |||
6 | Clean refrigerant and evacuate refrigerant circuit. | ||
| 000 588 04 82 00 Air conditioning service unit R134a | ||
| 000 588 10 82 00 R1234yf air conditioning service unit | ||
7 | Conduct vacuum test using air conditioning service unit. | ||
| 000 588 04 82 00 Air conditioning service unit R134a | ||
| 000 588 10 82 00 R1234yf air conditioning service unit | ||
Filling | |||
8 | Add new compressor oil to the refrigerant circuit according to the oil filling capacity noted during extraction. | ||
| Compressor oils (specification 362.1) | ||
| 000 588 04 82 00 Air conditioning service unit R134a | ||
| 000 588 10 82 00 R1234yf air conditioning service unit | ||
| |||
| |||
Depending on the repair case, correct oil filling capacity accordingly. | |||
Additional quantity of oil to be added when system suddenly looses fluid (e.g. line ruptured) | |||
Additional oil filling quantity after replacement of condenser | |||
Additional oil filling quantity after replacement of evaporator | |||
Additional oil filling quantity after replacement of desiccant cartridge | |||
Additional oil filling quantity after replacing low-pressure line | |||
Additional oil filling quantity after replacing high-pressure line | |||
Additional oil filling quantity after replacement of refrigerant compressor | |||
Additional oil filling quantity with detectable leakage | |||
9 | Fill air conditioning. | ||
| 000 588 04 82 00 Air conditioning service unit R134a | ||
| 000 588 10 82 00 R1234yf air conditioning service unit | ||
Air conditioning/automatic air conditioning | |||
| Check | ||
10 | Conduct pressure test using air conditioning service unit. | ||
| 000 588 04 82 00 Air conditioning service unit R134a | ||
| 000 588 10 82 00 R1234yf air conditioning service unit | ||
If a pressure drop is detected. | |||
| |||
Check air conditioning system for leakage. | |||
11 | Remove service connections (3, 4) of air conditioning service unit from filler connections (2). | ||
| 000 588 04 82 00 Air conditioning service unit R134a | ||
| 000 588 10 82 00 R1234yf air conditioning service unit | ||
12 | Screw on plugs (1). |
Air conditioning/automatic air conditioning |
Number | Designation | Model 118 (except 118.353/354/386/653/654/686), | Model 177.0 (except 177.053/054/086), 177.1 (except 177.186) | ||
BF83.00-P-1001-01P | Air conditioning/automatic air conditioning | Filling capacity for refrigerant | g | 530 | 630 |
Sheet R134a | - | - | |||
Sheet R1234yf | |||||
Air conditioning/automatic air conditioning |
Number | Designation | Model 118 (except 118.353/354/386/653/654/686), | Model 177.0 (except 177.053/054/086), 177.1 (except 177.186) | ||
BF83.00-P-1001-01P | Air conditioning/automatic air conditioning | Filling capacity for refrigerant | g | 590 | 690 |
Sheet R134a | |||||
Sheet R1234yf | - | - | |||
Air conditioning/automatic air conditioning |
Number | Designation | Model 118.354/654, 177.054, 247.754 | Model 118.354/654, 177.054, 247.754 | ||
BF83.00-P-1001-01P | Air conditioning/automatic air conditioning | Filling capacity for refrigerant | g | 1050 | 1200 |
Sheet R134a | - | ||||
Sheet R1234yf | - | ||||
Air conditioning/automatic air conditioning |
Number | Designation | Model 118.353/653, 177.053, 247.753 | Model 118.353/653, 177.053, 247.753 | ||
BF83.00-P-1001-01P | Air conditioning/automatic air conditioning | Filling capacity for refrigerant | g | 960 | 1010 |
Sheet R134a | - | ||||
Sheet R1234yf | - | ||||
Air conditioning/automatic air conditioning |
Number | Designation | Model 118.386/686, 177.086/186, 247.086/786 | Model 118.386/686, 177.086/186, 247.086/786 | ||
BF83.00-P-1001-01P | Air conditioning/automatic air conditioning | Filling capacity for refrigerant | g | 600 | 660 |
Sheet R134a | - | ||||
Sheet R1234yf | - | ||||
Air conditioning/automatic air conditioning |
Number | Designation | Model 177.945/951/984/987/988 | Model 247.6 (except 247.651) | ||
BF83.00-P-1001-01P | Air conditioning/automatic air conditioning | Filling capacity for refrigerant | g | 690 | 690 |
Sheet R134a | |||||
Sheet R1234yf | - | - | |||
Henviste dokumenter
- ah8330n000301a Oplysninger om håndtering af kølemidlet R134a
- ah8330n000401a Fremgangsmåde ved beskadiget eller utæt klimaanlæg
- ah8330n000501a Klimaanlæggets kredsløb og komponenter skal beskyttes mod fugt ved reparationer
- ah8330p000302a Oplysninger om håndtering af kølemiddel R1234yf
- ar8330p1761mfa
- ar8330p6521mfa
- ar8330p6521mfe
- ar8330p6521mfg
- as8300z000101a Fare for eksplosion ved svejse- og loddearbejde på det lukkede klimaanlæg. Fare for forgiftning ved indånding af overophedet kølemiddeldamp. Fare for personskade ved hud- og øjenkontakt med flydende kølemiddel
- as8300z000601a Fare for forgiftning ved indånding af overophedede kølemiddeldampe fra et klimaanlæg, der er påfyldt R134a. Fare for personskade ved hud- og øjenkontakt med flydende kølemiddel R134a og ved håndtering af dele, der er under tryk.
- as8300z000701a Brandfare som følge af antænding af kølemiddel R1234yf på varme dele. Fare for forgiftning ved indånding af overophedet kølemiddeldamp. Fare for personskade ved hud- og øjenkontakt med frigjort kølemiddel R1234yf og ved håndtering
- bb0040p036201a
- ws8300p0031b
- ws8300p0034b