Model | 171.4 (except 171.473) as of 3/3/08 |
with code 580 (Air-conditioning system) | |
except code 809 (Model year 2009) | |
Model | 171.4 (except 171.473) |
with code 580 (Air-conditioning system) | |
with code 809 (Model year 2009) | |
Model | 171.4 (except 171.473) |
with code 581 (Automatic air conditioning) | |
except code 809 (Model year 2009) | |
Model | 171.4 (except 171.473) |
with code 581 (Automatic air conditioning) | |
with code 809 (Model year 2009) | |
Model | 172.4 |
with code 580 (Air-conditioning system) | |
Model | 172.4 |
with code 581 (Automatic air conditioning) |
P83.30-4636-09
Shown on model 171.4 |
7 | Screw plug | 9 | Dismantling tool | 11 | Desiccant bag | ||
8 | Desiccant cartridge | 10 | Bracket |
Warning | Risk of poisoning caused by inhaling overheated refrigerant vapors from an air conditioning system containing R134a. Risk of injury to skin and eyes caused by contact with liquid R134a refrigerant and when working on pressurized parts | Never perform welding work on or near a closed air conditioning system. No smoking or open flames. Wear safety glasses and protective gloves. Work only in well ventilated rooms. Carry out repair work on the air conditioning system circuit only after the system has been evacuated. | |
Danger | Risk of fire due to ignition of R1234yf refrigerant on hot components. Risk of poisoning caused by inhaling overheated refrigerant vapors. Risk of injury to skin and eyes caused by contact with escaped R1234yf refrigerant and when working on pressurized parts. Risk of explosion due to formation of ignitable refrigerant/air mixtures | Never perform welding work on or near a closed air conditioning system. No smoking or open flames. Wear safety glasses and protective gloves. Work only in well ventilated rooms. Carry out repair work on the air conditioning system circuit only after the system has been evacuated. | |
Topical note | Protect air conditioning circuit and components from moisture when carrying out repair work | ||
Topical note | Procedure for a damaged or leaky air conditioning system | ||
Notes on handling refrigerant R1234yf | |||
Notes on handling refrigerant R134a | |||
| Remove | ||
1 | Drain air conditioning system | ||
2 | Disconnect filler connections from air conditioning service unit | ||
3 | Remove screw plug (7) from condenser | ||
4 | Insert dismantling tool (9) into holder (10) of desiccant cartridge (8) | Dismantling tool (9) is in repair kit. | |
5 | Remove desiccant cartridge (8) by rotating dismantling tool (9) left and right and simultaneously pulling up and out of the condenser | ||
| Install | ||
6 | Check packaging of new desiccant bag (11) for damage, then unpack desiccant bag (11) | | |
If packaging is leaky | |||
| |||
Dispose of desiccant bag (11). | |||
7 | Insert new desiccant bag (11) into new holder (10) | ||
| Compressor oils (specification 362.1) | ||
Moisten sealing ring of holder (10) using compressor oil. | |||
8 | Insert desiccant cartridge (8) into condenser | ||
| Compressor oils (specification 362.1) | ||
| |||
| |||
Moisten sealing ring of holder (10) with compressor oil. | |||
9 | Tighten screw plug (7) | ||
| Compressor oils (specification 362.1) | ||
Moisten sealing ring of screw plug (7) using compressor oil. | |||
Plugs to capacitor | |||
| Check | ||
10 | Evacuate air conditioning system, refill it, and then check the system to make sure that it functions correctly and does not leak |
Henviste dokumenter
- ah8330n000301a Oplysninger om håndtering af kølemidlet R134a
- ah8330n000401a Fremgangsmåde ved beskadiget eller utæt klimaanlæg
- ah8330n000501a Klimaanlæggets kredsløb og komponenter skal beskyttes mod fugt ved reparationer
- ah8330p000302a Oplysninger om håndtering af kølemiddel R1234yf
- ar8330p1760v
- as8300z000601a Fare for forgiftning ved indånding af overophedede kølemiddeldampe fra et klimaanlæg, der er påfyldt R134a. Fare for personskade ved hud- og øjenkontakt med flydende kølemiddel R134a og ved håndtering af dele, der er under tryk.
- as8300z000701a Brandfare som følge af antænding af kølemiddel R1234yf på varme dele. Fare for forgiftning ved indånding af overophedet kølemiddeldamp. Fare for personskade ved hud- og øjenkontakt med frigjort kølemiddel R1234yf og ved håndtering
- bb0040p036201a