D83.30-A024-79
1 | Refrigerant line | 5 | Screw | |
2 | Nut | 6 | Connecting flange | |
3 | Expansion valve | 7 | Refrigerant line | |
4 | Screw |
Danger | Risk of death when working on component parts and systems with U >= 30 V alternating voltage (AC) or U >= 60 V direct voltage (DC) | Do not touch damaged or defective live component parts and lines or non-insulated electrical connections and lines. | |
Warning | Risk of poisoning caused by inhaling overheated refrigerant vapors from an air conditioning system containing R134a. Risk of injury to skin and eyes caused by contact with liquid R134a refrigerant and when working on pressurized parts | Never perform welding work on or near a closed air conditioning system. No smoking or open flames. Wear safety glasses and protective gloves. Work only in well ventilated rooms. Carry out repair work on the air conditioning system circuit only after the system has been evacuated. | |
Topical note | General information on handling vehicles with high-voltage on-board electrical system and/or lithium-ion battery and/or gaseous-fuel drive system | ||
Topical note | Protect air conditioning circuit and components from moisture when carrying out repair work | ||
Notes on handling refrigerant R134a | |||
| Remove/install | ||
1 | Empty refrigerant circuit. | ||
2 | Remove nut (2). | Nut, refrigerant line to expansion valve | |
3 | Detach refrigerant line (1). | ||
| Compressor oils (specification 362.1) | ||
Seal opening in expansion valve (3). | |||
Installation: Replace sealing ring and moisten with compressor oil. | |||
Record plug | |||
4 | Unscrew bolt (4). | Bolt, refrigerant line to refrigerant compressor | |
5 | Remove screw (5). | | |
Bolt, refrigerant line to connecting flange | |||
6 | Detach refrigerant line (1) from refrigerant line (7) and from refrigerant compressor. | ||
| Compressor oils (specification 362.1) | ||
Seal openings in refrigerant line (7) and in refrigerant compressor. | |||
Installation: Replace sealing ring and moisten with compressor oil. | |||
7 | Remove refrigerant line (1). | | |
8 | Install in the reverse order. |
129 589 00 91 00
Record plug
Henviste dokumenter
- ah0000z030001a Generelle oplysninger ved køretøjer med højvoltsnet og/eller litium-ion-batteri og/eller gasdrivsystem samt personligt beskyttelsesudstyr
- ah8330n000301a Oplysninger om håndtering af kølemidlet R134a
- ah8330n000501a Klimaanlæggets kredsløb og komponenter skal beskyttes mod fugt ved reparationer
- ar8330d1760ts
- as0000z003501a Livsfare ved arbejde på komponenter og systemer med U >= 30 V vekselspænding (AC) eller U >= 60 V jævnspænding (DC)
- as8300z000601a Fare for forgiftning ved indånding af overophedede kølemiddeldampe fra et klimaanlæg, der er påfyldt R134a. Fare for personskade ved hud- og øjenkontakt med flydende kølemiddel R134a og ved håndtering af dele, der er under tryk.
- bb0040p036201a