1 | Electrical line |
E3 | Left taillamp |
E4 | Right taillamp |
P82.10-3378-01
P82.10-3377-01
P82.10-3379-09
2 | Nut | E3 | Left taillamp | E4 | Right taillamp |
| Remove/install | ||
Danger | Risk of explosion from explosive gas. Risk of poisoning and caustic burns from swallowing battery electrolyte. Risk of injury through burns to skin and eyes from battery acid or when handling damaged lead-acid batteries | No fires, sparks, open flames or smoking. Wear acid-resistant gloves, clothing and glasses. Only pour battery acid into suitable and appropriately marked containers. | |
1 | Disconnect battery ground line |
| |
Topical note | Notes on battery | ||
Model 461.302/304/305/331/332/333/334/340/342/344 | |||
2 | Remove the lens from the left taillamp (E3) or the right taillamp (E4) | ||
3 | Detach electrical lines (1) | Mark electrical lines (1). | |
4 | Unscrew nuts (2) in wheel well | ||
5 | Remove left taillamp (E3) or right taillamp (E4) | Installation: Check sealing, replace if necessary. | |
6 | Install in the reverse order | ||
7 | Read out fault memory and erase | ||
| Model 461.302/304/305/331/332/333/334/340/342/344 | ||
Stored faults which may have been caused by removed lines or simulation during installation or testing work must be processed and deleted from the fault memories after completing the work. |