ar5425d0002a
Test operation of starter lockout solenoid switch
Type ar · emne 54.25 · version 0104 · 2004-04-06
Gælder for: MODELS 902.061 /062, 903.061 /062 /063, 904.062 /063, 902.012 /072, 903.012 /013 /022 /072 /073, 904.012 /013 with ENGINE 111.979 with CODE (MS7) NGT (Natural Gas Transporter) sprinter MODELS 902.661 /662, 903.661 /662 /663, 904.662 /663, 902.612 /672, 903.612 /613 /622 /672 /673, 904.612 /613 with ENGINE 111.984 with CODE (MS7) NGT (Natural Gas Transporter) sprinter
Ikke tilgængelig på “da”; vises på Engelsk.
Placering
Funktionsgruppe 2 Chassis › 54 El-system, udrustning og instrumenter › 54.25 Kontakter — Serie 902 (modeller 012, 061, 062, 072, 612, 661, 662, 672) · Serie 903 (modeller 012, 013, 022, 061, 062, 063, 072, 073, 612, 613, 622, 661, 662, 663, 672, 673) · Serie 904 (modeller 012, 013, 062, 063, 612, 613, 662, 663)
EinPAS 15 Motor › 15.35 Starter › 15.35.12 Sensor/kontakt/ledningssæt — Serie 902 (modeller 012, 061, 062, 072, 612, 661, 662, 672) · Serie 903 (modeller 012, 013, 022, 061, 062, 063, 072, 073, 612, 613, 622, 661, 662, 663, 672, 673) · Serie 904 (modeller 012, 013, 062, 063, 612, 613, 662, 663)
EinPAS 29 kørselsgodkendelses-/sikringssystem › 29.25 Kørselsgodkendelse › 29.25.12 Sensor/kontakt/ledningssæt — Serie 902 (modeller 012, 061, 062, 072, 612, 661, 662, 672) · Serie 903 (modeller 012, 013, 022, 061, 062, 063, 072, 073, 612, 613, 622, 661, 662, 663, 672, 673) · Serie 904 (modeller 012, 013, 062, 063, 612, 613, 662, 663)
Gælder også for motorer/gearkasser: 111 979, 111 984
AR54.25-D-0002A
| Test operation of starter lockout solenoid switch
| 30.6.98
|
MODELS 902.061 /062, 903.061 /062 /063, 904.062 /063, 902.012 /072, 903.012 /013 /022 /072 /073, 904.012 /013 with ENGINE 111.979 with CODE (MS7) NGT (Natural Gas Transporter) sprinter
MODELS 902.661 /662, 903.661 /662 /663, 904.662 /663, 902.612 /672, 903.612 /613 /622 /672 /673, 904.612 /613 with ENGINE 111.984 with CODE (MS7) NGT (Natural Gas Transporter) sprinter
Illustration shows Sprinter prior to 2/2000
Components by analogy for Sprinter as of 2/2000
1 Solenoid switch
2 Permanent magnet
| Check
|
|
|
1
| Open fuel filler flap:
Start
Close fuel filler flap:
Start
|
If starting is possible with fuel filler flap open
|
|
|
|
| Exchange solenoid switch with connecting cable
| AR54.25-D-0001A
|