| Check | ||
Danger | Risk of fire/risk of explosion due to short circuit and escaping oxyhydrogen gas. Risk of (burn) injury caused by caustic burns to eyes, skin and mucous membranes from battery electrolyte/mist, short circuit and arcing. Risk of poisoning caused by swallowing battery electrolyte or absorption of lead through the skin or body orifices. Risk of death due to voltage U >= 30 V AC and U >= 60 V DC. | No fires, sparks, open flames, or smoking. Wear acid-resistant gloves, clothing, and glasses. Pour battery acid only into suitable and appropriately marked containers. | |
Topical note | Notes on battery | ||
1 | Read out fault memory | ||
| |||
Delete fault memory; rectify faults if necessary. | |||
Commercially available devices/tools | |||
2 | Open hood | ||
3 | Visual inspection of battery for external leakage | If leaks are found, battery must be replaced. | |
Dispose of defective battery properly and in an environmentally compatible manner. | |||
Refer to: | |||
| |||
Remove/install battery | |||
4 | Check battery using battery tester and compare measurement result with measurement tables | ||
Topical note | Notes on battery | ||
Assess condition of battery based on measurement tables; if necessary: | |||
Battery tester | |||
| |||
Charge battery | |||
Replace battery | |||
Dispose of defective battery properly and in an environmentally compatible manner. | |||
5 | Check fluid level; correct if necessary | Only if battery was not replaced. | |
|
450 589 15 21 00