1 | Electrical connector |
2 | Electrical line |
3 | O-ring |
4 | AdBlue® tank |
5 | Temperature sensor |
6 | SCR AdBlue® fill level and temperature sensor |
G49.20-A022-06
Warning | Risk of burn injuries and scalding when working at AdBlue lines and the components attached to them. Risk of injury to skin and eyes when handling AdBlue. Risk of poisoning caused by swallowing AdBlue | Pour AdBlue into suitable containers only. Wait until the pressure is released before starting any work on the exhaust aftertreatment system. | |
Notes on use, material properties and handling of AdBlue® | |||
| Remove/install | ||
1 | Switch off ignition. | ||
2 | Disconnect electrical connector (1). | ||
3 | Expose electrical line (2). | Installation: Replace removed cable ties. | |
4 | Clean AdBlue® tank (4) in area of SCR AdBlue fill level and temperature sensor® (6). | | |
5 | Turn SCR AdBlue fill level and temperature sensor® (6) to left (arrow) and remove from AdBlue® tank (4). | If AdBlue® drops get onto AdBlue® tank (4), remove resulting urea crystallizations with water and a lint-free cleaning cloth. | |
Installation: Check O-ring (3) for wear and damage, replace if necessary. | |||
6 | Install in the reverse order |
Henviste dokumenter
- ah1440n000101a Oplysninger om anvendelse og håndtering af AdBlue samt dets stofegenskaber
- as1440z000101a Fare for forbrænding og skoldning ved arbejde på AdBlue-rør og dermed forbundne komponenter. Fare for personskade på hud og øjne ved håndtering af AdBlue. Fare for forgiftning ved indtagelse af AdBlue