Manually check high-voltage on-board electrical system on high-voltage power distributor for absence of voltage

Type ar · emne 47.70 · version 0101 · 2019-12-20

Gælder for: Engine 780 in model 293

Ikke tilgængelig på “da”; vises på Engelsk.

Placering

Funktionsgruppe 1 Motor › 47 Brændstofsystem, energiforsyning drivline › 47.70 Energiforsyning drivline — Serie 293

EinPAS 16 Brændstof-/energiforsyning motor › 16.20 Bilens højspændingsnet › 16.20.1 Grundinformation — Serie 293

Gælder også for motorer/gearkasser: 780 ***

AR47.70-P-1010-03EQ

Manually check high-voltage on-board electrical system on high-voltage power distributor for absence of voltage

Danger

Risk of death when working on component parts and systems with U >= 30 V alternating voltage (AC) or U >= 60 V direct voltage (DC)

Do not touch damaged or defective live component parts and lines or non-insulated electrical connections and lines.

AS00.00-Z-0035-01A

Topical note

General information on handling vehicles with high-voltage on-board electrical system and/or lithium-ion battery and/or gaseous-fuel drive system

AH00.00-Z-0300-01A

Topical note

Information on preventing damage to electronic components due to electrostatic discharge

AH54.00-P-0001-01A

Notes on safety-relevant components

AH00.00-Z-0019-01A

000 588 07 19 00 Measuring instrument

WS47.00-N-0046A

Engine

780 in model 293

Manually check high-voltage on-board electrical system on high-voltage power    
	distributor for absence of voltage

000 589 94 63 00

Test adapter

All measurements in the high-voltage on-board electrical system are to be carried out only with the approved test adapter.
The high-voltage connection points or high voltage components will otherwise be damaged.

The proper function of the measuring instrument must be ensured before the start of inspection work by means of a function check in accordance with the manufacturer's specifications and by means of a visual check for external damage.

The proper function of the test adapter must be ensured before that start of inspection work by means of a visual check for external damage.

While performing the tests, fill out the printed test log (form) step by step.
After the end of the test and until the restart procedure, place the test log (form) behind the windshield.

Carefully connect the bushes using the probes of the measuring instrument.
The bushings or probes will otherwise be damaged.

Do not insert probes of the measuring instrument vertically into the bushes.
Otherwise, the measurement result may be false.

Manually check high-voltage on-board electrical system on high-voltage power    
	distributor for absence of voltage

P47.70-A039-07

Voltage measurements (A, B, C)

The voltage measurement (A) is performed between the red bush (Plus)/(HV+) and black bush (Minus)/(HV-) on the test adapter (6).
The voltage measurement (B) is performed between the red bush (Plus)/(HV+) and brown bush (ground connection)/(HV) on the test adapter (6).
The voltage measurement (C) is performed between the black bush (Minus)/(HV-) and brown bush (ground connection)/(HV) on the test adapter (6).
If the measuring instrument outputs an acoustic signal as a result instead of a voltage value during a voltage measurement (A, B, C), this is not a malfunction.
In this case, the detected voltage is below the display range of the measuring instrument, which is why the continuity check is activated automatically.
In this case, a voltage value of 0 V must be entered in the test log (form).

1

Using the measuring instrument, perform voltage measurements (A, B, C) on the bushes, assess them, and enter them in the test log.

If a voltage of  60 V DC is measured during all voltage measurements (A, B, C), the vehicle is deemed to be free of high voltage.
Absence of voltage has thus been determined.

If there is a direct voltage  60 V DC during one of the three voltage measurements (A, B, C):

Cancel voltage measurement (A, B, C), wait approx. 2 min, and then perform a second voltage measurement (A, B, C).

If there is still a direct voltage of  60 V DC during the second voltage measurement (A, B, C):

Cancel the manual test for absence of voltage and inform the market support team responsible immediately.