ar4725d0018a

Empty drain line

Type ar · emne 47.25 · version 0101 · 2016-12-16

Gælder for: Engine 111.984 in model 902, 903, 904 with code KL8 (Gas pressure container in load space) with code MY9 (Liquefied Gas Technology (LGT)) except code KL9 (Underfloor gas pressure container)

Ikke tilgængelig på “da”; vises på Engelsk.

Placering

Funktionsgruppe 1 Motor › 47 Brændstofsystem, energiforsyning drivline › 47.25 Ledninger, slanger — Serie 902 · Serie 903 · Serie 904

EinPAS 16 Brændstof-/energiforsyning motor › 16.10 Brændstofforsyning › 16.10.13 ledning/slange/ventil — Serie 902 · Serie 903 · Serie 904

Gælder også for motorer/gearkasser: 111 984

AR47.25-D-0018A

Empty drain line

01.12.2016

Engine

111.984 in model 902, 903, 904

with code KL8 (Gas pressure container in load space)

with code MY9 (Liquefied Gas Technology (LGT))

except code KL9 (Underfloor gas pressure container)

Empty drain line

1

Top cover

2

Gas reservoir cover

3

Manual valve

4

Electrical connection

D47.25-1114-06

Danger !

Risk of explosion due to escaping combustible gas or overheating of gas cylinders.Risk of injury caused by burns to skin and eyes. Risk of frostbite to body parts caused by escaping gas and by touching components near the valves when emptying gas cylinders. Risk of poisoning or suffocation caused by inhaling gas.

Remove any sources of ignition.
Protective clothing, safety gloves and safety glasses must always be worn.
Ensure that the work area is adequately ventilated.
When working on vehicles at ambient temperatures over 60 °C, all gas cylinders must be removed.

AS00.00-Z-0018-01A

Danger !

Risk of accident from vehicle starting off by itself when engine running. Risk of injury (bruises and burns) resulting from working on the engine while it is being started or when it is running.

Secure vehicle to prevent it from starting off by itself. Wear closed and snug-fitting work clothes. Do not touch hot or rotating parts.

AS00.00-Z-0005-01A

Discharge, fill

1

Remove upper cover (1)

2

Pry off cover on gas reservoir (2)

3

Close off manual valve (3)

4

Release and disconnect electrical connection (4)

5

Set selection switch to the gas position

After selection switch the green diode lights up.

6

Start the engine and allow it to run with the vehicle stationary until the engine stops on its own.

Installation: Switch off ignition.

Gas system is adequately emptied after engine stops.

7

Fill in reverse order

Henviste dokumenter