ar4725d0011b

Removing/installing solenoid valve for liquid phase

Type ar · emne 47.25 · version 0101 · 2016-12-16

Gælder for: Engine 111.984 in model 902, 903, 904 with code KL9 (Underfloor gas pressure container) with code MY9 (Liquefied Gas Technology (LGT)) except code KL8 (Gas pressure container in load space)

Ikke tilgængelig på “da”; vises på Engelsk.

Placering

Funktionsgruppe 1 Motor › 47 Brændstofsystem, energiforsyning drivline › 47.25 Ledninger, slanger — Serie 902 · Serie 903 · Serie 904

EinPAS 16 Brændstof-/energiforsyning motor › 16.10 Brændstofforsyning › 16.10.13 ledning/slange/ventil — Serie 902 · Serie 903 · Serie 904

Gælder også for motorer/gearkasser: 111 984

AR47.25-D-0011B

Removing/installing solenoid valve for liquid phase

01.12.2016

Engine

111.984 in model 902, 903, 904

with code KL9 (Underfloor gas pressure container)

with code MY9 (Liquefied Gas Technology (LGT))

except code KL8 (Gas pressure container in load space)

Removing/installing solenoid valve for liquid phase

1

Electrical connection

2

Cable tie

3

Gas line connection

4

Threaded connection

5

Liquid phase solenoid valve

6

Removal line connection

7

Screw/bolt

D47.25-1117-06

Danger !

Risk of explosion due to escaping combustible gas or overheating of gas cylinders.Risk of injury caused by burns to skin and eyes. Risk of frostbite to body parts caused by escaping gas and by touching components near the valves when emptying gas cylinders. Risk of poisoning or suffocation caused by inhaling gas.

Remove any sources of ignition.
Protective clothing, safety gloves and safety glasses must always be worn.
Ensure that the work area is adequately ventilated.
When working on vehicles at ambient temperatures over 60 °C, all gas cylinders must be removed.

AS00.00-Z-0018-01A

Danger !

Risk of accident from vehicle starting off by itself when engine running. Risk of injury (bruises and burns) resulting from working on the engine while it is being started or when it is running.

Secure vehicle to prevent it from starting off by itself. Wear closed and snug-fitting work clothes. Do not touch hot or rotating parts.

AS00.00-Z-0005-01A

Note on calculation of tightening torque when using insertion or socket tools with various effective lengths

AH00.00-P-0015-01CW

Remove/install

1

Empty drain line

AR47.25-D-0018B

2

Cut cable tie (2)

Installation: Replace cable tie (2).

3

Release and disconnect electrical connection (1)

4

Detach gas line connection (3)

Gas line to reducer

*BA47.25-N-1006-01K

5

Detach threaded connection (4)

6

Detach removal line connection (6) on liquid phase solenoid valve (5)

Union nut, drain line to liquid phase solenoid valve

*BA47.25-N-1005-01K

7

Remove screw/bolt (7) and liquid phase solenoid valve (5)

Bolt, liquid phase solenoid valve to bracket

*BA47.10-N-1011-02B

8

Install in the reverse order

9

Perform GAP

Compressed-gas tank, gas shutoff valve

Number

Designation

Engine 111.984

BA47.10-N-1011-02B

Bolt, liquid phase solenoid valve to bracket

Nm

10

Fuel lines/hoses

Number

Designation

Engine 111.984

BA47.25-N-1005-01K

Union nut, drain line to liquid phase solenoid valve

Nm

16

Fuel lines/hoses

Number

Designation

Engine 111.984

BA47.25-N-1006-01K

Gas line to reducer

Nm

16

Henviste dokumenter