D43.40-0045-09
1 Measuring point 1
2 Measuring point 2
3 Measuring point 3
7 Rotor
8 Pole flange
4 Measuring point 4
5 Measuring point 5
6 Measuring point 6
| Measure | ||
1 | Remove rotor (7) | Only if there is severe contamination: | |
2 | Clean rotor (7) and pole flanges (8) using wire brush | Only if there is severe contamination: | |
3 | Install rotor (7) | Only if rotor (7) was removed because of severe soiling. | |
4 | Use feeler gauge to measure gap widths at six points on the rotor (7) and the pole flange (8) opposite | When doing so, start at measuring point 1 (1) and determine the dimensions while working your way up to measuring point 6 (6). The corresponding feeler gauge must be able to be pulled through between the rotor (7) and pole flange (8) on the stator with a slight resistance. | |
Gap between rotor and stator | |||
5 | Calculate mean value from the six measurement values per rotor (7) | If the mean value is out of tolerance, the gap width must be adjusted on the corresponding rotor (7): | |
Adjust gap |
Test values for retarder (electric)