AR43.30-T-0004EL | Inspect shaped breather | 12.10.11 |
MODEL 613.355 with TRANSMISSION 714.66 with CODE (B10) Voith retarder R115 (integrated)
Voith Retarder VR 115 E - 153.000452xx
MODEL 613.355 /365 /455 /485 with TRANSMISSION 714.69 with CODE (B10) Voith retarder R115 (integrated)
Voith Retarder VR 115 E - 153.000452xx
MODEL 613.364 with TRANSMISSION 714.120 with CODE (B10) Voith retarder R115 (integrated)
Voith Retarder VR 115 E - 153.000452xx
MODEL 613.358 /388 with TRANSMISSION 714.140 with CODE (B10) Voith retarder R115 (integrated)
Voith Retarder VR 115 E - 153.000452xx
T43.30-0066-01
1 Valve element
2 Float
3 Test ring
| Checking | ||
1 | Remove profile ventilation | ||
2 | Check float (2) for surface damage (arrow) | ||
3 | Weigh float (2) and compare with specified value | If the specified weight is exceeded, replace the entire profile ventilation. Otherwise the retarder function may be destroyed. | |
4 | Place valve element (1) on float (2), weight it with the test ring (3) and fill the cavity between the float (2) and the upper edge of the valve element with spirit | If the fluid level changes within one minute, replace the entire profile ventilation. Otherwise the retarder function may be destroyed. | |
Test ring for shaped breather for retarder Order tool from Voith Turbo GmbH & Co. KG www.voith.com Order number H67.2757xx | |||
5 | Install in the reverse order. |
Test values of hydraulic retarder