AR35.50-W-0011A | Remove/install circuit breaker | 17.11.09 |
REAR AXLE 749.011
Dual-tired trailing axle (Nummek)
W35.50-1063-11
1 Cable
2 Plug connection
3 Union nut
4 Union nut
A Clearance
S96 Overload switch
| Remove | ||
1 | Separate line (1) on connector (2) and detach from the vehicle wiring harness in the further course of the work | ||
2 | Detach circuit breaker (S96) | ||
| Install | ||
3 | Unscrew union nut (3) and insert circuit breaker in the bracket | Insert circuit breaker until the clearance (A) is achieved. | |
4 | Tighten circuit breaker in this position | Lock both union nuts (3, 4). | |
5 | Route line (1) along the vehicle wiring harness and connect to the connector (2) | Use cable ties to fasten to the vehicle wiring harness. |
Check values for dual-tired trailing axle