ar2010g129002df

Remove/install connection piece of coolant pump to cylinder head

Type ar · emne 20.10 · version 0100 · 2009-07-06

Gælder for: ENGINE 906.90 in MODEL 000.001 with CODE (MS8) Natural gas engine

Ikke tilgængelig på “da”; vises på Engelsk.

Placering

Funktionsgruppe 1 Motor › 20 Motorkøling › 20.10 Kølevæskepumpe, kølevæsketermostat — Serie 000 (modeller 001) · Serie 906 (modeller 90*)

EinPAS 15 Motor › 15.25 Motorkølesystem › 15.25.30 pumpe/termostat/forvarmningsapparat — Serie 000 (modeller 001) · Serie 906 (modeller 90*)

AR20.10-G-1290-02DF

Remove/install connection piece of coolant pump to cylinder head

Danger!

Risk of injury to skin and eyes caused by scalding from contact with hot coolant spray. Risk of poisoning caused by swallowing coolant.

Do not open cooling system unless coolant temperature is below 90°C. Open cap slowly and release the pressure. Do not pour coolant into beverage containers.

Wear protective gloves, protective clothing and safety glasses.

AS20.00-Z-0001-01A

Coolant pump, coolant thermostat

Number

Designation

Engines
900.9, 902.9, 904.9, 906.9

BA20.10-N-1003-01L

Bolt, connection piece of coolant pump to cylinder head

Nm

50

Remove/install connection piece of coolant pump to cylinder head

W20.10-1011-11

1 Take off coolant hose (2) at coolant manifold (1).

Installation: Replace sealing rings.

2 Loosen coolant hoses (3) and push back onto the coolant lines (4).

3 Disconnect control line (5) from electropneumatic pressure converter (EPW) (Y87) to turbocharger at connector hose.

Remove/install connection piece of coolant pump to cylinder head

G20.10-3138-11

4 Take off coolant hose (6) at connection piece (10).

5 Disconnect electrical connector of engine wiring harness (7) from coolant temperature sensor (B65).

6 Detach engine wiring harness (7) at control line (5).

7 Disconnect line (5) to the turbocharger at connector hose and remove.

8 Remove bolts (8) and remove crankcase breather line (9).

Installation: Tighten bolts (8).

9 Pull connecting piece (10) together with coolant manifold (1) upwards and out of connection fitting (11).

Installation: Replace the seal in connecting piece (10).

10 Pull connection fitting (11) out of the coolant pump.

Installation: Replace connector fitting (11).

11 Install in the reverse order.