Connection scheme |
1 | Multimeter |
2 | DC clip-on probe |
3 | Load tester |
4 | On-board electrical system battery |
5 | Alternator |
6 | Starter |
7 | On-board electrical system battery ground point |
S15.40-4549-06
Warning | Risk of accident from vehicle starting off by itself when engine running. Risk of injury (bruises and burns) resulting from working on the engine while it is being started or when it is running. | Secure vehicle to prevent it from starting off by itself. Wear closed and snug-fitting work clothes. Do not touch hot or rotating parts. | |
| Check | ||
1 | Fulfill preconditions for alternator test | ||
2 | Check charging voltage of alternator (5) | ||
3 | Attach multimeter (1) with DC clip-on probe (2) according to connecting scheme at electrical line of alternator (5) | ||
4 | Attach load tester (3) according to connection scheme at on-board electrical system battery (4) | ||
| 000 588 03 19 00 Load tester | ||
5 | Start engine | ||
6 | Check charging current of alternator (5) | Check charging current at higher engine rpms, whereby on-board electrical system battery (4) is loaded with load tester (3). Change load resistance until maximum charging current, depending on version of alternator (5), is reached. In doing so the charging voltage must not fall below 12.7 V. | |
If the maximum charging current is not reached. | |||
| |||
Check diodes of alternator (5) | |||
7 | Turn off engine | ||
8 | Remove multimeter (1) with DC clip-on probe (2) | ||
9 | Remove load tester (3) | ||
| 000 588 03 19 00 Load tester |