D15.40-1117-06
1 Contact protection
2 Electrical cable, circuit 30 (B+)
3 Terminal 61 (D+) electrical connector
4 Bolts
5 Bracket
G2/8 Generator
| Remove/install | ||
1 | Disconnect battery ground line | ||
2 | Release tension on poly-V-belt and remove belt pulley from alternator (G2/8) | ||
3 | Take off contact protection (1) and detach terminal 30 (B+) electrical line (2) from alternator (G2/8) | | |
4 | Disconnect terminal 61 (D+) electrical connector (3) from alternator (G2/8) | ||
5 | Unscrew bolts (4), place bracket (5) aside and remove alternator (G2/8) | | |
6 | Install in the reverse order |
Alternator
Henviste dokumenter
- ar1322d1202ng
- ar5410d0003sd Afbrydelse, tilslutning af batteriets stelledning