P15.18-A024-09
Shown on model 247.014 |
1 | Release and disconnect electrical connector (4) from AdBlue® metering valve (Y129) and expose electric line. |
2 | Release electrical connections(5) and disconnect. |
3 | Release and disconnect electrical connector (6). |
4 | Release and disconnect electrical connector (2) from NOx sensor control unit upstream of the SCR catalytic converter (N37/7). |
5 | Release and disconnect electrical connector (3) from NOx sensor control unit downstream of the SCR catalytic converter (N37/8). |
6 | Expose engine wiring harness (1) on the right side and place down to one side. |
7 | Remove cover (9). |
8 | Unscrew nut and remove electric line (10) . |
9 | Release and disconnect electrical connector (7) from the CDI control unit (N3/9). |
10 | Remove engine wiring harness (1) on the left side from the air filter housing (8) and place down to one side. |
11 | Connect in reverse order. |
Henviste dokumenter
- ah0000n000101a Oplysninger om selvlåsende bolte og møtrikker
- ah5400p000101a Oplysninger med henblik på at undgå skader på elektroniske komponenter på grund af elektrostatisk afladning