AR14.40-W-2015C | Remove/install SCR air pressure limiter solenoid valve | 22.3.11 |
ENGINES 900.9 in MODEL 375.1, 970, 972, 975, 976 with CODE (MS4) BlueTec 4
ENGINES 900.9 in MODEL 375.1, 970, 972, 975, 976 with CODE (MS5) BlueTec 5
ENGINES 902.9 in MODEL 375.3, 950.5 /6, 952.5 /6, 953.6, 954.5, 957 with CODE (MS4) BlueTec 4
ENGINES 902.9 in MODEL 375.3, 950.5 /6, 952.5 /6, 953.6, 954.5, 957 with CODE (MS5) BlueTec 5
ENGINES 902.9 in MODEL 375.1, 970, 972, 974, 975, 976 with CODE (MS4) BlueTec 4
ENGINES 902.9 in MODEL 375.1, 970, 972, 974, 975, 976 with CODE (MS5) BlueTec 5
ENGINES 924.9 in MODEL 958.0, 970, 972, 974, 975, 976 with CODE (MS4) BlueTec 4
ENGINES 924.9 in MODEL 958.0, 970, 972, 974, 975, 976 with CODE (MS5) BlueTec 5
ENGINES 925.9 in MODEL 970, 972, 974 with CODE (MS4) BlueTec 4
ENGINES 925.9 in MODEL 970, 972, 974 with CODE (MS5) BlueTec 5
ENGINES 926.9 in MODEL 950.5 /6, 952.5 /6, 953.6, 954.5, 957, 958.2 with CODE (MS4) BlueTec 4
ENGINES 926.9 in MODEL 950.5 /6, 952.5 /6, 953.6, 954.5, 957, 958.2 with CODE (MS5) BlueTec 5
ENGINES 926.9 in MODEL 958.0 with CODE (MS4) BlueTec 4
ENGINES 926.9 in MODEL 958.0 with CODE (MS5) BlueTec 5
W14.40-1171-06
Shown on model 950.5
1 Compressed air inlet
2 Compressed air outlet
3 Union nut
4 Electrical connector
5 Union nut
7.03 Overflow valve without return flow
30.03 Pressure limiting valve with vent
Y106 SCR air pressure limiter solenoid valve (33.01)
| Remove/install | ||
| Notes on self-locking nuts and bolts | ||
| Notes on compressed air connection systems | ||
1 | Switch off ignition | ||
2 | Disconnect electrical connector (4) at SCR air pressure limiter solenoid valve (Y106) | After turning off engine, individual lines are scavenged with compressed air for about 3 minutes. For this reason, do not start any work on the exhaust aftertreatment system before this time has passed. | |
3 | Remove compressed air line at compressed air inlet (1) | First loosen union nut (5) | |
| |||
4 | Remove compressed air line at compressed air outlet (2) | First loosen union nut (3) | |
| |||
5 | Remove SCR air pressure limiter solenoid valve (Y106) | | |
6 | Install in the reverse order | ||
7 | Charge compressed air system up to the shutoff pressure and test for leaktightness |
Compressed air lines
Number | Designation | Model | Model | ||
BA00.18-N-1002-01A | VOSS "232" compressed-air connection system | M161.5 | Nm | 12 | 12 |
M221.5 | Nm | 12 | 12 | ||
Compressed air lines
Number | Designation | MODELS | Model | ||
BA00.18-N-1002-01A | VOSS "232" compressed-air connection system | M161.5 | Nm | 12 | 12 |
M221.5 | Nm | 12 | 12 | ||
Exhaust aftertreatment, Blue Tec
Henviste dokumenter
- ah0000n000101a Oplysninger om selvlåsende bolte og møtrikker
- ah0018n000101a Oplysninger om trykluftstikforbindelsessystemer