P13.22-2189-09
1 | Poly-V-belt | 4 | Bolts | 6 | Poly-V belt tensioning device | ||
2 | Bolts | 5 | Electrical connector | M56 | Vacuum pump | ||
3 | Circulation pump holder |
| Remove/install | ||
Warning | Risk of injury. Moving parts can pinch, crush or, in extreme cases even sever extremities. | No parts of the body or limbs should be within the operating area of mechanical components when moving components. | |
Danger | Risk of death when working on component parts and systems with U >= 30 V alternating voltage (AC) or U >= 60 V direct voltage (DC) | Do not touch damaged or defective live component parts and lines or non-insulated electrical connections and lines. | |
1 | Remove cylinder head cover trim | ||
2 | Remove fan unit | ||
3 | Remove screws (2) | ||
4 | Unhook bracket for the circulation pumps (3) in the upper area and lay outside the working area to the front | ||
5 | Remove screw/bolts (4) | ||
6 | Disconnect electrical connection (5) and lay vacuum pump (M56) to the side until the poly-V belt tensioning device (6) is accessible | ||
7 | Loosen poly-V-belt (1) and remove | ||
| Pin for locking poly-V belt tensioning device | ||
Installation: | |||
Installation: Fit on poly-V belt (1) as per routing diagram and tension. | |||
| |||
Routing diagram for poly-V belt | |||
Tension poly-V-belt | |||
8 | Check poly-V belt (1) for damage and wear; replace if necessary | ||
| |||
9 | Install in the reverse order |
Henviste dokumenter
- ap1322p1352cw Kontrol af kileremmen for slid i det synlige område
- ar1322p390201t
- ar1322p390202cd
- ar1322p390204t
- ar2040p5050ew
- as0000z000901a Fare for personskade som følge af klemning af legemsdele, i værste fald fare forafskæring af legemsdele ved indgreb i mekanikken
- as0000z003501a Livsfare ved arbejde på komponenter og systemer med U >= 30 V vekselspænding (AC) eller U >= 60 V jævnspænding (DC)
- wf5850p132502a