AR01.10-S-2400-15PB | Detach/attach lines and hoses for removal of engine | ||
Danger | Risk of explosion caused by fuel igniting, risk of poisoning caused by inhaling and swallowing fuel as well as risk of injury to eyes and skin caused by contactwith fuel. | No fires, sparks, open flames or smoking. Pour fuels into suitable and appropriately marked containers only. | |
Warning | Risk of injury to skin and eyes suffering scalding from contact with hot coolantspray. Risk of poisoning from swallowing coolant. | Do not open cooling system unless coolant temperature is below 90 °C. Open cap slowly and release the pressure. Do not pour coolant into beverage containers. |
454 589 00 37 00
Hose clamp pliers
129 589 00 91 00
Record plug
S01.10-4651-08
1 | Remove coolant hose (1). |
To do so, open clamp on coolant hose (1) using hose clamp pliers and remove coolant hose (1). |
Collect escaping coolant; seal connections with a set of stop plugs. |
Installation: Check clamp. |
Depending on findings |
|
Replace clamp if necessary. |
2 | Remove coolant hose (2). |
To do so, open clamp on coolant hose (2) using hose clamp pliers and remove coolant hose (2). |
Collect escaping coolant; seal connections with a set of stop plugs. |
Installation: Check clamp. |
Depending on findings |
|
Replace clamp if necessary. |
3 | Remove fuel hose (3) from fuel line. |
To do so, release fuel hose (3) on connector coupling (4). |
4 | Place fuel hose (3) outside of working area. |
To do so, remove fuel hose (3) from bracket (5) and retaining clip (6). |
5 | Remove fuel hose (7). |
To do so, open clamp (8) on fuel hose (7) using hose clamp pliers and remove fuel hose (7). |
Installation: Check clamp (8). |
Depending on findings |
|
Replace clamp (8). |
6 | Place fuel hose (7) outside of working area. |
To do so, remove fuel hose (7) from bracket (9). |
7 | Remove vacuum hose (10) from intake manifold and place outside working area. |
To do so, open clamp on vacuum hose (10) using hose clamp pliers and remove vacuum hose (10). |
Installation: Check clamp. |
Depending on findings |
|
Replace clamp if necessary. |
8 | Install in the reverse order. |
Henviste dokumenter
- as2000z000101a Risiko for skoldningsskader på hud og øjne pga. sprøjtende, varm kølervæske. Risiko for forgiftning ved indtagelse af kølervæske
- as4700z000101a Fare for eksplosion ved tænding, fare for forgiftning ved indånding og indtagelse af brændstof samt fare for hud- og øjenskader ved kontakt med brændstof