ar0019d010008a

Protect repair area after cable repairs

Type ar · emne 00.19 · version 0102 · 2019-02-14

Gælder for: Model all (Heavy transporter, Light transporter)

Ikke tilgængelig på “da”; vises på Engelsk.

Placering

Funktionsgruppe 0 Samlet › 00 Samlet køretøj › 00.19 El-system køretøj, alle forbindelser — Serie 900 (modeller 9**) · Serie 902 (modeller 9**) · Serie 904 (modeller 918, 919, 924, 925, 938, 943, 957) · Serie 906 (modeller 917, 918, 924, 953)

EinPAS 25 bilens ledningsnet/netværk/multifunktion › 25.25 Hovedledningssæt › 25.25.30 Reparationsledningssæt — Serie 900 (modeller 9**) · Serie 902 (modeller 9**) · Serie 904 (modeller 918, 919, 924, 925, 938, 943, 957) · Serie 906 (modeller 917, 918, 924, 953)

Gælder også for motorer/gearkasser: 139 ***, 254 ***, 256 ***, 272 ***, 276 ***, 282 ***, 457 9**, 541 9**, 542 9**, 608 ***, 700 4**, 700 420, 700 421, 700 422, 700 423, 715 3**, 715 5**, 722 6**, 722 9**, 724 ***, 724 0**, 724 033, 724 044, 724 045, 724 1**, 724 103, 724 114, 724 115, 724 120, 725 ***, 725 0**, 725 035, 725 037, 725 038, 725 085, 725 1**, 739 390, 739 391, 739 395, 739 396, 739 397, 739 398, 739 399, 740 698, 743 3**, 743 4**, 743 498, 746 971, 924 9**, 924 910, 925 9**, 926 9**

AR00.19-D-0100-08A

Protect repair area after cable repairs

Caution

Risk of injury caused by burns to skin and eyes. Risk of poisoning caused by inhaling fumes when working with heat-shrinkable tubing.

Work in well ventilated rooms only. Wear safety glasses with side protection and protective gloves.

AS00.19-Z-0001-01A

Notes on cable protection

AH00.19-P-1000-11A

000 588 00 84 00 Heat gun

WS54.00-P-0049B

Model

all (Heavy transporter, Light transporter)

Protect repair area after cable repairs

1

Slide heat-shrinkable tube over the repair area.



2

Heat the heat-shrinkable tube using hot air blower until it lies evenly against the repair area.


Protection of repair area with heat-shrinkable tube

P54.18-2623-01

Protect repair area after cable repairs

3

Lay corrugated hose over repair point.



4

Wrap insulation tape around corrugated hose at both ends.


Protection of repair point by corrugated hose

P54.18-2624-01

Protect repair area after cable repairs

5

Wrap duct tape around repair point to match the original condition.


Duct tape is used for visual harmonization of the repair point and to protect against chafing. In vehicle areas with higher loads (e.g. engine compartment), duct tape should only be used in combination with other (watertight) safety precautions.


Repair point protection through wrapping with duct tape

D54.18-1121-01