AR00.19-D-0100-08A | Protect repair area after cable repairs | ||
Caution | Risk of injury caused by burns to skin and eyes. Risk of poisoning caused by inhaling fumes when working with heat-shrinkable tubing. | Work in well ventilated rooms only. Wear safety glasses with side protection and protective gloves. | |
Notes on cable protection | |||
| 000 588 00 84 00 Heat gun |
1 | Slide heat-shrinkable tube over the repair area. |
2 | Heat the heat-shrinkable tube using hot air blower until it lies evenly against the repair area. |
Protection of repair area with heat-shrinkable tube |
P54.18-2623-01
3 | Lay corrugated hose over repair point. |
4 | Wrap insulation tape around corrugated hose at both ends. |
Protection of repair point by corrugated hose |
P54.18-2624-01
5 | Wrap duct tape around repair point to match the original condition. |
Duct tape is used for visual harmonization of the repair point and to protect against chafing. In vehicle areas with higher loads (e.g. engine compartment), duct tape should only be used in combination with other (watertight) safety precautions. |
Repair point protection through wrapping with duct tape |
D54.18-1121-01
Henviste dokumenter
- ah0019p100011a Oplysninger om ledningsbeskyttelse
- as0019z000101a Fare for personskade ved forbrænding af hud og øjne, fare for forgiftning ved indånding af dampe i forbindelse med bearbejdning af krympeslanger